USER MANUAL

 

PCE-LSM 

Summary of Contents for LSM

Page 1: ...029 03 976 99 29 info warensortiment de www warensortiment de PCE Group Ib rica S L Tel 34 967 543 548 Fax 34 967 543 542 info pce iberica es www pce iberica es PCE Group Italia S R L Tel 39 0583 975...

Page 2: ...ter or a printer 15 14 Special functions description Error Marcador no definido 15 Legend 17 16 Normal weighing 17 17 Weighing with tare 17 18 Weigh summing rECIPE 18 19 Pieces counting PCS 19 20 Auto...

Page 3: ...g screw notified body stamps and green M sticker placed on balance name plate Legal verification is valid for 3 years until verification seals are not broken As weight indication depends on gravitatio...

Page 4: ...n 2 pan support under the pan 3 pan ring 4 LCD display 5 keys 6 rotating legs 7 water level Balances AD510 AD1000 AD3000 and AD2 5 AD5 1 pan 2 pan support under the pan 3 pan ring 4 LCD display 5 keys...

Page 5: ...support under the pan 3 pan ring 4 LCD display 5 keys 6 rotating legs 7 water level REAR VIEW 7 6 1 2 4 5 ON OFF Adjust switch RxD receiver TxD transmitter gnd chassis RS232C Feeder Feeder Printer or...

Page 6: ...nsmission calibration navigation mode switch MENU menu I switch off standby indicator result stabilisation bar indicator total load indicator 0 100 indicator OFF stand by mode Max Min d e II metrologi...

Page 7: ...0 5g 0 5g 0 5g Reading unit d 0 01g 0 01g 0 01g 0 01g 0 01g Verification unit e 0 05g 0 1g 0 1g 0 1g 0 1g Tare range 250g 500g 1000g 2000g 3000g Accuracy class II Working temperature 18 33 C Weighing...

Page 8: ...onnel only To avoid fire risk use a feeder of an appropriate type supplied with a balance Pay attention that supply voltage is compatible with specified technical data Do not use a balance when its co...

Page 9: ...per working conditions and user friendly operating setup the balance on an even flat surface leaving necessary room for easy access maintain proper working temperature avoid strong air drafts vibratio...

Page 10: ...pan 150mm is connected to pan base 5 AD10 AD12 Put elements 2 on the mandrel sticking out of a balance put a pan 1 6 Plug a feeder to the power socket at the back of the balance Leave the pan empty a...

Page 11: ...11 9 Start up After switching on the balance performs automatic self test Program version Zeroing Ready to work C 1 C 5 0 000g AC...

Page 12: ...lt should be read when the indicator lights which signalises stabilisation of a result 5 When the balance is not used but it is necessary to be ready to work immediately it can be switched off by pres...

Page 13: ...advised to contact the nearest service to calibrate a balance 12 Adjusting a balance If balance indications exceed permissible error it is necessary to adjust a balance To calibrate a balance use cal...

Page 14: ...nctions Press T to choose CALIbr and CAL on Press several times to select desired weight value It is advised to use as great weight value as possible Press T to accept When LOAD appears put the weight...

Page 15: ...ons are available on the website www axis pl RS 232C Test free serial port testing program ProCell residual program for cooperation with Microsoft EXCEL and other Microsoft Windows applications demo v...

Page 16: ...ting serial port parameters setting percentage weighing weighing unit change grams carats pounds prescriptions making calibration options Other special functions may be enabled as an option on custome...

Page 17: ...matic change 16 Normal weighing When a pan is empty and indication is different than zero press T key Weighing result should be read when the indicator lights 17 Weighing with tare A balance is equipp...

Page 18: ...ious series of weighing Before weighing each ingredient A B C etc remember to tare the balance To read aggregated sum of all previously weighed components press key or use rEC oFF option To return to...

Page 19: ...ng unit and sample weight used in first phase is bigger than 100 reading units To leave function press F key and then with T key chose PCS and PCS oFF Note Err 3 communicate signalises that a sample w...

Page 20: ...rt working mode selection LPt This function enables to select serial port working mode When function is active weighing result with successive number is printed automatically after putting and replaci...

Page 21: ...hen working as a single scale the value should be 0 continuous transmission without using key approx 10 results per second SEnd 0 1 Default parameters underlined To set desired transmission parameters...

Page 22: ...s Options dAt oFF deactivate date printout dAt on activate date printout using key dAt SEt change date and time The example at the left presents how to set current date and time Time format h gg mm g...

Page 23: ...nt format depending on the reference sample weight value For values of 0 3 5 of weighing range the format is 100 0 for values 3 5 35 it is 100 00 and 35 100 100 00 The function has the following optio...

Page 24: ...er pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable To differ ActIV function from the function menu indicator is displayed at the l...

Page 25: ...ance please contact our nearest service Error communicates Communicate Possible cause Remedy C 1 6 over 1 min selftests failed if displayed more than 1 minute contact an authorised service L pan missi...

Page 26: ...e a sticker with two digit number of the year in which the mark was affixed and the number of the Notified Body responsible for EC verification a green metrology sticker with M mark a protective seal...

Page 27: ...27 Notes...

Page 28: ...a vision of the measurement technique http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmos...