background image

 

 

©  PCE Instruments 

 

5.9 Battery 

 

If the meter does not turn on or the battery indicator is lit, replace the 9 V battery as 
soon as possible. 

 

To do  this,  press  the  arrow  icon of  the  battery compartment  and  slide  it  down. After 
inserting a new battery, close the cover again. Make sure the polarity is correct. 
 

 

Warranty 

You  can  read  our  warranty  terms  in  our  General  Business  Terms  which  you  can  find  here: 

https://www.pce-instruments.com/english/terms

 

Disposal 

For  the  disposal  of  batteries  in  the  EU,  the  2006/66/EC

 

directive  of  the  European  Parliament 

applies. Due to the contained pollutants, batteries must not be disposed of as household waste. 
They must be given to collection points designed for that purpose. 
 
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use 
them or give them to a recycling company which disposes of the devices in line with law. 
 
For  countries  outside  the EU,  batteries  and  devices  should  be  disposed  of  in accordance  with 
your local waste regulations. 
 
If you have any questions, please contact PCE Instruments. 
 

 

 
 
 
 

 

Summary of Contents for DT 50

Page 1: ...50 Tachometer User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 1...

Page 2: ...1 Device 3 3 2 Display description 3 4 Operation 4 5 1 Switching the meter on and off 4 5 2 Measurement 4 5 3 Hold function 4 5 4 Max Min Avg measured value 4 5 5 Switching the backlight on and off 4...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...in Measuring rate 0 5s over 120 rpm Storage 60 individual data storage Automatic shutdown After 20 s Power supply 9V block battery Operating conditions 0 50 C 32 122 F 10 90 rh Storage conditions 10...

Page 5: ...acklight 6 On off key 7 Auto key 8 Max Min Avg key 9 Recording key 10 Battery compartment 3 2 Display description 1 Measurement indicator 2 HOLD icon 3 Laser icon 4 Battery level indicator 5 MAX MIN a...

Page 6: ...aximum value of the measurement Press the Max button 8 twice to read the minimum value Press the Max button 8 three times to read the average value AVG 5 5 Switching the backlight on and off Press the...

Page 7: ...ish terms 6 Disposal For the disposal of batteries in the EU the 2006 66 EC directive of the European Parliament applies Due to the contained pollutants batteries must not be disposed of as household...

Page 8: ...e stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co...