PCB Load&Torque 1380-01A Installation And Operating Manual Download Page 11

Model Number

1380-01A

ROD END LOAD CELL

Revision: D
ECN #: 43827

Performance

ENGLISH

SI 

Measurement Range

500 lbf

2224 N

[5]

Sensitivity(± 10 %)

2 mV/V

2 mV/V

[6]

Non-Linearity

≤ 0.25 % FS

≤ 0.25 % FS

Hysteresis

≤ 0.15 % FS

≤ 0.15 % FS

Non-Repeatability

≤ 0.05 %RO

≤ 0.05 %RO

Resonant Frequency

9 kHz

9 kHz

Environmental

Overload Limit

750 lbf

3336 N

Load Limit(Side Force, F

X

 or F

Y

)

250 lbf

1112 N

[3]

Load Limit

(Bending Moment, M

X

 or M

Y

)

750 inf-lb

85 Nm

[3]

Load Limit

(Axial Torque, M

Z

)

500 inf-lb

56 Nm

[3]

Temperature Range(Operating)

-20 to +200 °F

-28 to +93 °C

Temperature Range

(Compensated)

+70 to +170 °F

+21 to +77 °C

Temperature Effect on Output(Maximum)

± 0.01 %Reading/°F

± 0.018 %Reading/°C

[4]

Temperature Effect on Zero Balance(Maximum)

± 0.005 %FS/°F

± 0.009 %FS/°C

[4]

Electrical

Bridge Resistance

350 Ohm

350 Ohm

[1]

Excitation Voltage(Recommended)

10 VDC

10 VDC

[2]

Insulation Resistance

>5x10

9

 Ohm

>5x10

9

 Ohm

Zero Balance

≤ 1 % FS

≤ 1 % FS

Output Polarity

Positive

Positive

Output Polarity

+Tension

+Tension

Physical

Size (Diameter x Height)

1.50 in x 4.25 in

38.1 mm x 107.9 mm

[7]

Weight

0.5 lb

227 g

Mounting Thread

3/4 - 16 Male

No Metric Equivalent

Mounting Thread

3/4 - 16 Female

No Metric Equivalent

Cover Material

Anodized Aluminum

Anodized Aluminum

Sensor Material

Anodized Aluminum

Anodized Aluminum

Sensing Element

Strain Gage

Strain Gage

Deflection at Full Scale Capacity

0.0004 in

0.010 mm

Electrical Connector

PT02E-10-6P

PT02E-10-6P

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

NOTES:

[1]Nominal.
[2]Calibrated at 10 VDC, usable 5 to 20 VDC or VAC RMS.
[3]Singularly applied, i.e. no other extraneous loads.
[4]Over compensated operating temperature range.
[5]FS - Full Scale.
[6]RO - Rated Output.
[7]See Outline Drawing 45488 for complete dimensions.

OPTIONAL ACCESSORIES: 

Model 181-012A PT06A-10-6S(SR)
Model 8311-01-10A CABLE

PCB Load & Torque, Inc.
24350 Indoplex Circle
Farmington Hills, MI 48335
UNITED STATES
Phone: 866-684-7107
Fax: 716-684-0987
E-Mail: [email protected]
Web site: 
http://www.pcbloadtorque.com

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard 

model except where noted below. More than one option may be used.

Entered: AP

Engineer: PE

Sales: JC

Approved: JSD

Spec Number:

Date: 2/17/2015

Date: 2/17/2015

Date: 2/17/2015

Date: 2/17/2015

45841 

Summary of Contents for Load&Torque 1380-01A

Page 1: ...allation and Operating Manual For assistance with the operation of this product contact PCB Load Torque Inc Toll free 866 684 7107 24 hour SensorLine 716 684 0001 Fax 248 888 8266 E mail LTInfo pcbloa...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ounding Considerations 3 6 0 CALIBRATION 3 6 1 Calibration Certificate Description 3 6 1 1 Measured Output 4 6 1 2 Hysteresis 4 6 1 3 Best Fit Output 4 6 1 4 Strain Gage Measurements 4 6 1 5 Shunt Cal...

Page 7: ...od end load cells must be even and centered Compensation linkages e g rod end bearing alignment couplers are recommended to help minimize load misalignment When installing fixtures be sure to thread t...

Page 8: ...The instrument or control system is grounded through its power cord Ground loops and measuring system wiring may result in unstable or noisy signals A simple test with a voltmeter connected between th...

Page 9: ...load on a load cell The calibration certificate will indicate which leg of the bridge to apply the shunt resistor to for both tension and compression load simulation Typically tension is simulated by...

Page 10: ...ignal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 10 0 CALIBRATION REPAIR SERVICES PCB Load Torque offers calibration and...

Page 11: ...ing Thread 3 4 16 Female No Metric Equivalent Cover Material Anodized Aluminum Anodized Aluminum Sensor Material Anodized Aluminum Anodized Aluminum Sensing Element Strain Gage Strain Gage Deflection...

Page 12: ...10 DECIMALS XX 01 XXX 005 DECIMALS X 0 3 XX 0 13 45488 PCB Load Torque Inc claims proprietary rights in the information disclosed hereon Neither it nor any reproduction thereof will be disclosed to o...

Reviews: