PCB Piezotronics Y1403-05ADB Installation And Operating Manual Download Page 16

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

ANGLES

  

`

 .5 DEGREES

24350 Indoplex Circle, Farmington Hills,MI 48335
(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

ANGLES

  

`

 

.5 DEGREES

FILLETS AND RADII 

.015 MAX 

FILLETS AND RADII 

0.38 MAX

OUTLINE DRAWING

49605

1 OF 1

FULL

1203/1403 SERIES, PT CONNECTOR

LOW PROFILE LOAD CELLS

PTE

11/21/11

DECIMALS     XX   ±.01

XXX   ±.005

DECIMALS    X   ± 0.3

XX   ± 0.13

A

B

B

A

4

9

6

0

5

PCB Load & Torque Inc. claims proprietary rights  in 
the  information disclosed hereon.  Neither it nor any 
reproduction thereof will be disclosed to others without
the written consent of PCB Load and Torque Inc.

1.37 [34.8]

.12 [3.0]

n

1.34 [34.0]

n

4.12 [104.6]

.62 [15.7]

"THREAD" 

x

.88 [22.3]

(STANDARD LOAD CELLS 5/8-18 UNF-3B,

METRIC "M" LOAD CELLS M16 X 2.0 4H,

SPECIAL LOAD CELL 1"-14UNS-3B)

 

n

3.500 [88.90]

n

4.12 [104.6]

n

1.34 [34.0]

1.13 [28.7]

.5 [13]

n

.25 [6.4]

4X 

 

x

.25 [6.4]

     (SPANNER WRENCH)

CONNECTOR "A"
PT02E-10-6P CONNECTOR
WIRING CODE: TYPICAL
PIN A +EXC
PIN B +SIG
PIN C -SIG
PIN D -EXC
PIN E N/C
PIN F N/C
 

n

3.500 [88.90]

22.5°

8X 1/4-28 UNF-2B 

x

.50 [12.7]

"THREAD" 

x

.88 [22.3]

(STANDARD LOAD CELLS 5/8-18UNF-3B,

METRIC "M" LOAD CELLS M16X2.0 4H,

SPECIAL LOAD CELL 1"-14UNS-3B)

2.50 [63.5]

.030 [.76]

45°

"THREAD" 

x

.88 [22.3]

(STANDARD LOAD CELLS 5/8-18 UNF-3B,

METRIC "M" LOAD CELLS M16 X 2.0 4H,

SPECIAL LOAD CELL 1"-14UNS-3B)

2.67 [67.8]

2.54 [64.6]

 W/CONN. PROTECTOR

n

1.34 [34.0]

.12 [3.0]

CONNECTOR "A"
PT02E-10-6P CONNECTOR
WIRING CODE: TYPICAL
PIN A +EXC
PIN B +SIG
PIN C -SIG
PIN D -EXC
PIN E N/C
PIN F N/C
 

.030 [.76]

"THREAD" 

x

.88 [22.3]

(STANDARD LOAD CELLS 5/8-18UNF-3B,

METRIC "M" LOAD CELLS M16X2.0 4H,

SPECIAL LOAD CELL 1"-14UNS-3B)

n

4.12 [104.6]

45°

2.67 [67.8]

2.54 [64.6]

 W/CONN. PROTECTOR

45°

n

.281 [7.14]

8X 

 THRU

22.5°

8X 1/4-28 X 1.75 [44.5] 12 POINT FLANGE BOLT

CONNECTOR "B"
DUAL BRIDGE ONLY

REVISIONS

REV

DESCRIPTION

ECO

E

HUB DIAMETER WAS 1.25 [31.8] - 10.05.16, PTE

46027

1

1

SUPPLIED WITH MATING FASTENERS.

1203, M1203, 1403 AND M1403 SERIES LOAD CELLS

INCLUDING DUAL BRIDGE

1203, M1203, 1403 AND M1403 SERIES LOAD CELLS W/BASES

INCLUDING DUAL BRIDGE

1203, M1203, 1403 AND M1403 SERIES BASES

n

1.34 [34.0]

MDF

11/21/11

JDM

11/21/11

WIRING CODE FOR "T" SERIES LOAD CELLS
 
     PIN A   +EXC.
     PIN B   +SIG.
     PIN C   -SIG.
     PIN D   -EXC.
     PIN E    TEDS DATA
     PIN F    TEDS GROUND

2

2

2

3

3

MODEL 084A90 CONNECTOR PROTECTOR SHOWN:
OPTIONAL ON ALL 1203/M1203 SERIES AND 1403/M1403 SINGLE BRIDGE LOAD CELLS
STANDARD ON 1403/M1403 SERIES DUAL BRIDGE LOAD CELLS

3

.21 [5.4]

.21 [5.4]

CONNECTOR "B"
DUAL BRIDGE ONLY

.25 [6.4]

.62 [15.7]

4X Ø.25 [6.4] 

x

.25 [6.4]

    (SPANNER WRENCH)

(

n

1.34 [34.0])

Summary of Contents for Y1403-05ADB

Page 1: ...LOAD CELL DUAL BRIDGE Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 6...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...LECTRICAL INSTALLATION 5 5 1 Electrical Drawing Western Regional Std 5 5 2 Cable Grounding Considerations 5 6 0 CALIBRATION 5 6 1 Calibration Certificate Description 5 6 1 1 Measured Output 6 6 1 2 Hy...

Page 7: ...the parts under test have completed the planned fatigue test cycles 3 0 OVERVIEW Dual bridge fatigue rated load cells are specifically designed for repetitive testing Applications include material te...

Page 8: ...ote that the performance of the load cell may be affected if the factory installed mounting base is removed or modified 4 2 Mounting Load Cell to a Standard Base or Custom Fixture If the load cell is...

Page 9: ...ctor Protector 1 Remove the 4 40 x 1 4 button head cap screws from the connector using a 1 16 hex wrench as shown in Figure 7 2 Carefully pull the connector from the load cell Take care to not break o...

Page 10: ...wiring may result in unstable or noisy signals A simple test with a voltmeter connected between the power cord ground and the structure on which the load cell is mounted can confirm that the structur...

Page 11: ...s are adjusted such that the error due to eccentric loading is less than 0 1 per inch of offset Side loads moments and torque must be limited to avoid electrical or mechanical damage to the load cell...

Page 12: ...tion certificate and adjust the span or gain until the display reads the force value stated on the certificate 4 Repeat steps 1 3 to verify that a valid calibration setting has been obtained 5 If poss...

Page 13: ...ridge resistances A D excitation and B C the signal leads 9 Check bridge balance 10 Keep a record of your observations correct problems or contact PCB factory for assistance 11 2 1 Estimating Bridge B...

Page 14: ...factory for any reason For calibration services if possible a copy of the purchase order covering the requested services should be included with the returned load cell 13 0 WARRANTY Standard warranty...

Page 15: ...63 50 mm 8 Weight 6 4 lb 2 9 kg Mounting Thread 5 8 18 UNF 3B No Metric Equivalent Sensing Element Strain Gage Strain Gage Mounting Torque 200 in lb 23 Nm Deflection at Full Scale Capacity 0 001 in 0...

Page 16: ...LOAD CELLS 5 8 18UNF 3B METRIC M LOAD CELLS M16X2 0 4H SPECIAL LOAD CELL 1 14UNS 3B 2 50 63 5 030 76 45 THREAD x 88 22 3 STANDARD LOAD CELLS 5 8 18 UNF 3B METRIC M LOAD CELLS M16 X 2 0 4H SPECIAL LOA...

Reviews: