Model Number

602D91

INDUSTRIAL ICP® ACCELEROMETER

Revision: C
ECN #: 50817

P erfo rm an ce

EN G L ISH

SI

Sensitivity(± 10 %)

100 mV/g

10.2 mV/(m/s²)

[1]

Measurement Range

± 50 g

± 490 m/s²

Frequency Range(± 3 dB)

30 to 480,000 cpm

0.5 to 8,000 Hz

[2]

Resonant Frequency

1,500 kcpm

25 kHz

[3]

Broadband Resolution(1 to 10,000 Hz)

350 µg

3,434 µm/sec

2

[3]

Non-Linearity

± 1 %

± 1 %

[4]

Transverse Sensitivity

≤ 7 %

≤ 7 %

En viro n m en tal

Overload Limit(Shock)

5,000 g pk

49,050 m/s² pk

Temperature Range

-65 to +250 °F

-54 to +121 °C

Temperature Response

See Graph

See Graph

[3]

Enclosure Rating

IP68, IP69K

IP68, IP69K

Electrical

Settling Time(within 1% of bias)

≤ 3.0 sec

≤ 3.0 sec

[3]

Discharge Time Constant

≥ 0.3 sec

≥ 0.3 sec

Excitation Voltage

18 to 28 VDC

18 to 28 VDC

Constant Current Excitation

2 to 20 mA

2 to 20 mA

Output Impedance

< 150 Ohm

< 150 Ohm

Output Bias Voltage

8 to 12 VDC

8 to 12 VDC

Spectral Noise(10 Hz)

8.0 µg/√Hz

78.5 (µm/sec

2

)/√Hz

[3]

Spectral Noise

(100 Hz)

5 µg/√Hz

49.1 (µm/sec

2

)/√Hz

[3]

Spectral Noise

(1 kHz)

4 µg/√Hz

39.2 (µm/sec

2

)/√Hz

[3]

Electrical Isolation(Case)

> 10

8

 Ohm

> 10

8

 Ohm

P h ysical

Size (Length x Height x Width)

1.55 in x 0.845 in x 0.74 in

39.4 mm x 21.5 mm x 18.8

mm

Weight

2.61 oz

74.0 gm

Mounting Thread

1/4-28 Male

No Metric Equivalent

[5]

Mounting Torque

2 to 5 ft-lb

2.7 to 6.8 Nm

Sensing Element

Ceramic

Ceramic

Sensing Geometry

Shear

Shear

Housing Material

316L Stainless Steel

316L Stainless Steel

Sealing

Welded Hermetic

Welded Hermetic

Electrical Connector

4-Pin, M12

4-Pin, M12

Electrical Connection Position

Side

Side

[6]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Piezotronics, Inc.

M

 - Metric Mount

Supplied Accessory: Model M081B97 Captive Mounting Bolt, M6 x 1 x 25 mm long, hex head (1)

TO

 - Temperature Output

Temperature Output Range

+36 to +250 °F

+2 to +121 °C

Temperature Scale Factor

5.56 mV/°F + 32

+10 mV/°C

Electrical Connections(Pin A)

Acceleration Signal / Power

Acceleration Signal / Power

Electrical Connections

(Pin B)

Ground

Ground

Electrical Connections

(Pin C)

No Connection

No Connection

Electrical Connections

(Pin D)

Temperature Output

Temperature Output

OP TION A L  VERSION S

Optional versions have identical specifications and accessories as listed for the standard model except

where noted below. More than one option may be used.

N OTES:

[1]Conversion Factor 1g = 9.81 m/s².
[2]The high frequency tolerance is accurate within ±10% of the specified frequency.
[3]Typical.
[4]Zero-based, least-squares, straight line method.
[5]1/4-28 has no equivalent in S.I. units.
[6]See PCB Declaration of Conformance PS023 for details.

Date: 06/11/2020

Date: 06/11/2020

Date: 06/11/2020

Date: 06/11/2020

62199

Entered: LK

Engineer: GD

Sales: MC

Approved: BAM

Spec Number:

Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: [email protected]

3425 Walden Avenue, Depew, NY 14043

SU P P L IED A C C ESSORIES:

Model 081B97 Captive Mounting Bolt 316SS - 7/16 HEX 1/4-28 UNF (1)
Model ICS-2 NIST-traceable single-point amplitude response calibration at 6000 cpm (100 Hz) for
each axis (1)

Summary of Contents for M602D91

Page 1: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 2: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 3: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 4: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 5: ...ON A ECN NUMBER 49766 Operating Guide with Enclosed Warranty Information 3424 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI Piezoelectric IC...

Page 6: ...ply low frequency and high frequency measurements Shear design sensors are preferred because of their inherent insensitivity to adverse environmental influences such as case or base strain and thermal...

Page 7: ...wer gain which is extremely close to unity and independent of input voltage Also the diode can be changed to supply higher currents for driving long cable lengths Constant current diodes as shown in F...

Page 8: ...nics However when operating AC coupled signal conditioners with readout devices having an input impedance of less than one megaohm thelow frequencyrangemaybeaffected 4 1 STANDARD STUD MOUNT This mount...

Page 9: ...derside of the mounting base Firmly press down on the assembly to displace any extra adhesive remaining under the base See Figure7 METHOD 2 Direct Adhesive Mount For restrictions of space or for conve...

Page 10: ...interference or radio frequency interference EMI or RFI To avoid ground loops thereshouldonlybeonegroundin the system It is recommended for permanent installations that the sensor becase isolatedand...

Page 11: ...ate Also any current not used by the cable goes directly to power the internal electronicsandwillcreateheat Thismaycausethesensorto exceed its maximum temperature specification For this reason donotsu...

Page 12: ...er the meter or LED and allow the sensor to power up If a faulty condition is monitored first check all system connections then check the functionality of the cable and signal conditioner If the syste...

Page 13: ...and former MIL STD 45662A and uses equipment directly traceable to NIST This assures an accurate calibration of relevant specifications The following includes a broad overview of the Back to Back Cal...

Page 14: ...A of constant current to extend battery life while continuous monitoring systems offer more current in order to drive longer cables Figure 16 shows a typical system for a sensor with integral electron...

Page 15: ...eive assistance via e mail at imi pcb com or visit our website at www pcb com 11 0 CUSTOMER SERVICE WARRANTY IMI a division of PCB Piezotronics guarantees Total Customer Satisfaction If at any time fo...

Page 16: ......

Page 17: ...M12 Electrical Connection Position Side Side 6 All specifications are at room temperature unless otherwise specified In the interest of constant product improvement we reserve the right tochange spec...

Page 18: ...CIMALS X 0 3 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 62198 1 OF 1 3X ACCELEROMETER WITH SIDE EXIT 4 PIN M12 CONNECTOR XXX 005 JDM 2 12 16 AF 2 12 16 GCD 2 12 16 B C A D 62198 PCB Piezotronics Inc...

Reviews: