Certificate:
1632187
Master Contract:
184981
Project:
2655913
Date Issued:
September 26, 2013
DQD 507 Rev. 2012-05-22
Page: 5
Models EX64xA0y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters
of: Ui (V max) = 30V, Ii (I max) = 100mA, Pi = 1W, Li = 1.06 uH, Ci = 0; when installed per installation Dwg
27535; Temp Code T4 @ Max Ambient 80 Deg C.
Models 9942VCRT Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters
of: Ui (V max) = 30V, Ii (I max) = 100mA, Pi = 1W, Ci = 0, Li = 1.06 uH; when installed per installation Dwg
36578; Temp Code T4 @ Max Ambient 80 Deg C.
Models EX64xA1y and EX64xA6y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with
entity parameters of: Ui (V max) = 30V, Ii (I max) = 100mA, Pi = 1W, Ci = 61 nF, Li = 306 µH; when installed
per installation Dwg 27535; Temp Code T4 @ Max Ambient 80 Deg C.
Models EXTO64xA3y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters
of: Ui (V max) = 28V, Ii (I max) = 120mA, Pi = 1W, Li = 1.06 uH, Ci = 0; when installed per installation Dwg
27537; Temp Code T4 @ Max Ambient 80 Deg C.
Models EXTO64xA1y and EXTO64xA6y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive
with entity parameters of: Ui (V max) = 28V, Ii (I max) = 120mA, Pi = 1W, Ci = 61 nF, Li = 306 µH; when
installed per installation Dwg 27537; Temp Code T4 @ Max Ambient 80 Deg C.
Models EXRV64xA0y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters
of: Ui (V max) = 28V, Ii (I max) = 120mA, Pi = 1W, Li = 121.06 uH Ci = 0; when installed per installation
Dwg 30540; Temp Code T4 @ Max Ambient 80 Deg C.
Models EXRV64xA1y and EXRV64xA6y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive
with entity parameters of: Ui (V max) = 28V, Ii (I max) = 120mA, Pi = 1W, Ci = 61 nF, Li = 426 µH; when
installed per installation Dwg 30540; Temp Code T4 @ Max Ambient 80 Deg C.
Models CS64xB9y Vibration Sensors, input rated 28V dc max, 20mA; non-incendive with entity parameters of:
Ui (V max) = 30V, Ii (I max) = 100mA, Pi = 1W, Ci = 0, Li = 1.06 uH; when installed per Dwg 56140; Temp
Code T4 @ Max Ambient 80 Deg C.
Notes:
1. For Canadian Installations, senor case must be bonded to ground according to Section 18-182 of the CEC,
Part 1.
2. For US Installations, sensor case must be bonded to ground according to Article 501.16 of the NEC.
3. The “x” in the model code may be a 2, 3, 7 or 8, which denotes variations in frequency response range of the
sensors. The “y” in the model code may be a 0, 1 or 2, which denotes variations in sensor sensitivity.
APPLICABLE REQUIREMENTS
CAN/CSA-C22.2 No. 0-M91 - General Requirements – Canadian Electrical Code, Part II
C22.2 No. 142-M1987(R2009) - Process Control Equipment