wiring
Remove outer cover of the enclosure by loosening the four screws located on the front panel. Strip cable
approximately 1/8
”
to 3/16
”
(Note the length of the conductor as not to short any neighboring cables). Feed
cables through cable grips.
To connect cable, push down on the top spring loaded terminal strip connector. Push the conductor into the
connector (front), then remove the screwdriver. This will clamp the cable conductors onto the terminal strips.
Slightly pull on the conductor to make sure that it was installed correctly. Tighten the cable clamp nut located on
the outside of the enclosure. This will hold the cable jacket and also protect the internal connections from
environmental contaminants.
figure 1
–
typical input channel wiring
CH1
CH2
CH3
CH4
positive input
connect the sensor
’
s positive input
negative input
connect the sensor
’
s negative input
shield
connect the sensor
’
s shield, if applicable