Manual 21354 Rev E 
ECN 50523 

 

 

 

 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Summary of Contents for IMI SENSORS 684a16

Page 1: ...sure Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail imi...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...NITORING Models 684A1 684A4 Panel Meter Enclosures Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1...

Page 7: ...ts Introduction Page 3 General Features Specifications Page 3 Installation and Wiring Page 4 Terminal Block Diagram Page 5 Dimension Drawing Page 6 ESD Sensitivity Page 7 Ordering Information Page 8 W...

Page 8: ...able installation of wiring Different Panel Meters Controllers can be mixed within one Enclosure Panel Meter Controller comes factory installed and wired to its respective terminal blocks Enclosure is...

Page 9: ...is for the shield typically a drain wire SHIELD GND Panel Meter Controller Power is connected to the respective terminal block located in the lower middle position Line Neutral and Earth Ground are co...

Page 10: ...PAGE 5 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Terminal Block Diagram Figure 1...

Page 11: ...PAGE 6 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Dimension Drawing Figure 2 Model 684A18 Shown...

Page 12: ...scharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug...

Page 13: ...s will occupy 20 holes 5 When 5 meters are ordered 26 cord grips are installed 1 Power 25 Signal Blanks will occupy 15 holes 6 When 6 meters are ordered 31 cord grips are installed 1 Power 30 Signal B...

Page 14: ...or to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proced...

Page 15: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 16: ...ions are at room temperature unless otherwise specified In the interest of constant product improvement we reserve the right to change specifications without notice ICP is a registered trademark of PC...