PCB Piezotronics IMI SENSORS 682 Series Operating Manual Download Page 14

 

PAGE 10 

 

SENSO

RS AN

D INS

TRUME

N

TATIO

N F

OR MAC

HINE 

CON

DITION M

ONIT

ORIN

G

 

S10: 

 

10g, 1ips, 20mils

 

S11: 

 

5g, 0.5ips, 10mils

 

S12:

 

 

Off = 0-5Vdc Output, On = 0-10Vdc Output 

Internal DIP Switch Setting 
 

The Internal DIP Switch of the 682 Series must be configured for the Full Scale Output of the ICP

®

 Sensor 

connected to it. This is accomplished by removing the front cover and sliding the PC Board out of the Signal 
Conditioner. Once removed, the DIP switch should be configured per one of the conditions in the following table.  
 

Range Setting 

S1 

S2 

S3 

S4 

S5 

S6 

S7 

S8 

S9 

S10 

S11 

5g RMS 

ON 

ON 

OFF 

OFF

 

OFF 

OFF

 

ON 

OFF 

OFF

 

OFF

 

ON 

5g Peak 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

OFF 

ON 

OFF

 

OFF

 

ON 

10g RMS 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

ON 

OFF 

OFF

 

ON 

OFF

 

10g Peak 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

OFF 

ON 

OFF

 

ON 

OFF

 

20g RMS 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

ON 

OFF 

ON 

OFF

 

OFF

 

20g Peak 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

OFF 

ON 

ON 

OFF

 

OFF

 

0.5 in/sec RMS 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

ON 

OFF 

OFF

 

OFF

 

ON 

0.5 in/sec Peak 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

OFF 

ON 

OFF

 

OFF

 

ON 

1.0 in/sec RMS 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

ON 

OFF 

OFF

 

ON 

OFF

 

1.0 in/sec Peak 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

OFF 

ON 

OFF

 

ON 

OFF

 

2.0 in/sec RMS 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

ON 

OFF 

ON 

OFF

 

OFF

 

2.0 in/sec Peak 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

OFF

 

ON 

ON 

OFF

 

OFF

 

10 mils p-p 

OFF 

OFF

 

OFF 

OFF

 

ON 

ON

 

OFF

 

OFF

 

OFF

 

OFF

 

ON 

20 mils p-p 

OFF 

OFF

 

OFF 

OFF

 

ON 

ON

 

OFF

 

OFF

 

OFF

 

ON 

OFF

 

40 mils p-p 

OFF 

OFF

 

OFF 

OFF

 

ON 

ON

 

OFF

 

OFF

 

ON 

OFF 

OFF

 

                                                                   

S12 

OFF 

0-5Vdc Output 

S12 

ON 

0-10Vdc Output 

 

Note: Factory Default Setting is 1.0in/sec Peak, 0-5Vdc Output 

 
 

 
 
Filter Module Location

 

 

The Filter Modules are utilized to set the cutoff frequency of the internal band pass filter circuit. The 682 Series 
comes standard with Modules preinstalled. If a different cutoff frequency is desired, the preinstalled module can 
be removed by simply pulling it out of the MOD socket, and replacing it with a different module. The module is 
labeled with the type of filter, Low Pass or High Pass, and the cutoff frequency. Module location is as follows: 
 

MOD1:

   

Low Pass (LP) Filter Module Location 

MOD2:

   

High Pass (HP) Filter Module Location 

 

 
 
 
 

Warning:

 Do not make any adjustments to the internal potentiometers. These potentiometers are used for 

factory calibration and adjusting them will require return of the 682 Series unit to the factory for recalibration. 

Summary of Contents for IMI SENSORS 682 Series

Page 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 5: ...Series 4 20mA Din Rail ICP Signal Conditioner Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800...

Page 6: ...f Contents Introduction Page 3 Block diagram Page 3 General Features Page 4 Installation and Wiring Page 5 Configuring the 682BX3 Page 9 ESD Sensitivity Page 12 Ordering Information Page 13 Warranty S...

Page 7: ...Displacement can be converted to a 4 20mA signal by simple DIP Switch selection internal to the Din Rail enclosure An additional standard feature of the 682 Series is the ability to convert the tempe...

Page 8: ...ion ranges include Acceleration g s Velocity in sec Displacement mils p p 5 00 0 50 10 0 10 00 1 00 20 0 20 00 2 00 40 0 Internal DIP switch selection for Peak or RMS Utilization of Filter Modules for...

Page 9: ...luids or machine oils IMI Sensors recommends mounting the 682BX3 in a type NEMA 4 enclosure to protect the electronics from contamination Dimension Drawing The Power LED is Green which turns on when t...

Page 10: ...closure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devic...

Page 11: ...Pin 9 RV Pin 10 RV 4 to 20mA Temperature Output Pins 11 to 12 Pin 11 4 to 20mA Temperature Output Pin 12 4 to 20mA Temperature Output 4 to 20mA Vibration Output Pins 13 to 14 Pin 13 4 to 20mA Vibrati...

Page 12: ...PAGE 8 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram 682 Series Signal Conditioner Signal Conditioner Power Supply 682A01 Power Supply...

Page 13: ...d Sensor Power Select Jumper The DIP switch is used to configure the signal conditioner for various sensor and vibration ranges The Filter Modules are installed to set the High and Low cutoff frequenc...

Page 14: ...OFF 1 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON OFF ON OFF 2 0 in sec RMS OFF OFF ON ON OFF OFF ON OFF ON OFF OFF 2 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON ON OFF OFF 10 mils p p OFF OFF OFF OFF O...

Page 15: ...NSTRUMENTATION FOR MACHINE CONDITION MONITORING Sensor Power Jumper Configuration Factory Default Note If there is no DC bias on the input signal this will trigger the Open short detection which subtr...

Page 16: ...nt may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can dama...

Page 17: ...the level of protection may be exceeded by extremely high voltage Ordering Information IMI Part Number 682A X 3 Frequency Response Isolation 0 3Hz to 10kHz Standard 1 3Hz to 1kHz 2 10Hz to 10kHz 3 10...

Page 18: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Page 19: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 20: ...LLETS AND RADII 0 07 0 13 OUTLINE DRAWING 40537 1 OF 1 FULL 4 20 DIN RAIL CONDITIONER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JDM 5 31 16 ECB 5 31 16 CPH 5 31 16 40537 PCB Piezotronics Inc claim...

Reviews: