PCB Piezotronics IMI SENSORS 682 Series Operating Manual Download Page 1

 

 

 

The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual. 

  

 

 

Service 

–  Due  to  the  sophisticated 

nature  of  the  sensors  and  associated 
instrumentation 

provided 

by 

PCB 

Piezotronics,  user  servicing  or  repair  is 
not  recommended  and,  if  attempted, 
may  void  the  factory  warranty.  Routine 
maintenance,  such  as  the  cleaning  of 
electrical  connectors,  housings,  and 
mounting  surfaces  with  solutions  and 
techniques  that  will  not  harm  the 
physical  material  of  construction,  is 
acceptable. Caution should be observed 
to  ensure  that  liquids  are  not  permitted 
to  migrate  into  devices  that  are  not 
hermetically 

sealed. 

Such 

devices 

should  only  be  wiped  with  a  dampened 
cloth  and  never  submerged  or  have 
liquids poured upon them.   
 

Repair 

–  In  the  event  that  equipment 

becomes 

damaged 

or 

ceases 

to 

operate,  arrangements  should  be  made 
to  return  the  equipment  to  PCB 
Piezotronics for repair. User servicing or 
repair  is  not  recommended  and,  if 
attempted, 

may 

void 

the 

factory 

warranty.     
 

Calibration 

–  Routine  calibration  of 

sensors  and  associated  instrumentation 
is  recommended  as  this  helps  build 
confidence  in  measurement  accuracy 
and 

acquired 

data. 

Equipment 

calibration 

cycles 

are 

typically 

established  by  the  users  own  quality 
regimen.  When  in  doubt  about  a 
calibration cycle, a good 

“rule of thumb” 

is to recalibrate on an annual basis. It is 

also  good  practice  to  recalibrate  after 
exposure  to  any  severe  temperature 
extreme, 

shock, 

load, 

or 

other 

environmental  influence,  or  prior  to  any 
critical test.  
 
PCB  Piezotronics  maintains  an  ISO- 
9001  certified  metrology  laboratory  and 
offers  calibration  services,  which  are 
accredited  by  A2LA  to  ISO/IEC  17025, 
with  full  traceability  to  SI  through 
N.I.S.T.  In  addition  to  the  normally 
supplied  calibration,  special  testing  is 
also  available,  such  as:  sensitivity  at 
elevated  or  cryogenic  temperatures, 
phase  response,  extended  high  or  low 
frequency  response,  extended  range, 
leak 

testing, 

hydrostatic 

pressure 

testing,  and  others.  For  information  on 
standard 

recalibration 

services 

or 

special  testing,  contact  your  local  PCB 
Piezotronics 

distributor, 

sales 

representative,  or  factory  customer 
service representative.   
 

Returning  Equipment 

– 

Following 

these  procedures  will  ensure  that  your 
returned  materials  are  handled  in  the 
most 

expedient 

manner

Before 

returning 

any 

equipment 

to 

PCB 

Piezotronics, 

contact 

your 

local 

distributor,  sales  representative,  or 
factory  customer  service  representative 
to  obtain  a  Return 

Warranty,  Service, 

Repair,  and  Return  Policies  and 
Instructions 

Materials  Authorization 

(RMA)  Number.  This  RMA  number 
should be clearly marked on the outside 
of  all  package(s)  and  on  the  packing 

Service, Repair, and Return 
Policies and Instructions 

Summary of Contents for IMI SENSORS 682 Series

Page 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 5: ...Series 4 20mA Din Rail ICP Signal Conditioner Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800...

Page 6: ...f Contents Introduction Page 3 Block diagram Page 3 General Features Page 4 Installation and Wiring Page 5 Configuring the 682BX3 Page 9 ESD Sensitivity Page 12 Ordering Information Page 13 Warranty S...

Page 7: ...Displacement can be converted to a 4 20mA signal by simple DIP Switch selection internal to the Din Rail enclosure An additional standard feature of the 682 Series is the ability to convert the tempe...

Page 8: ...ion ranges include Acceleration g s Velocity in sec Displacement mils p p 5 00 0 50 10 0 10 00 1 00 20 0 20 00 2 00 40 0 Internal DIP switch selection for Peak or RMS Utilization of Filter Modules for...

Page 9: ...luids or machine oils IMI Sensors recommends mounting the 682BX3 in a type NEMA 4 enclosure to protect the electronics from contamination Dimension Drawing The Power LED is Green which turns on when t...

Page 10: ...closure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devic...

Page 11: ...Pin 9 RV Pin 10 RV 4 to 20mA Temperature Output Pins 11 to 12 Pin 11 4 to 20mA Temperature Output Pin 12 4 to 20mA Temperature Output 4 to 20mA Vibration Output Pins 13 to 14 Pin 13 4 to 20mA Vibrati...

Page 12: ...PAGE 8 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram 682 Series Signal Conditioner Signal Conditioner Power Supply 682A01 Power Supply...

Page 13: ...d Sensor Power Select Jumper The DIP switch is used to configure the signal conditioner for various sensor and vibration ranges The Filter Modules are installed to set the High and Low cutoff frequenc...

Page 14: ...OFF 1 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON OFF ON OFF 2 0 in sec RMS OFF OFF ON ON OFF OFF ON OFF ON OFF OFF 2 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON ON OFF OFF 10 mils p p OFF OFF OFF OFF O...

Page 15: ...NSTRUMENTATION FOR MACHINE CONDITION MONITORING Sensor Power Jumper Configuration Factory Default Note If there is no DC bias on the input signal this will trigger the Open short detection which subtr...

Page 16: ...nt may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can dama...

Page 17: ...the level of protection may be exceeded by extremely high voltage Ordering Information IMI Part Number 682A X 3 Frequency Response Isolation 0 3Hz to 10kHz Standard 1 3Hz to 1kHz 2 10Hz to 10kHz 3 10...

Page 18: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Page 19: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 20: ...LLETS AND RADII 0 07 0 13 OUTLINE DRAWING 40537 1 OF 1 FULL 4 20 DIN RAIL CONDITIONER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JDM 5 31 16 ECB 5 31 16 CPH 5 31 16 40537 PCB Piezotronics Inc claim...

Reviews: