Warranty 

IMI instrumentation is warranted against defective material workmanship for 1 year unless otherwise expressly 

specified.  Damage to instruments caused by incorrect power or misapplication, is not covered by warranty.  

If 

there are any questions regarding power, intended application, or general usage, please consult with your local 

sales contact or distributor.  

Batteries or expendable hardware items are not covered by warranty. 

 

Service 

Because of the sophisticated nature of IMI instrumentation, field repair is typically 

NOT

 recommended and may 

void any warranty.  If factory service is required, return the instrumentation according to the “Return Procedure” 

stated below.  

A repair and/or replacement quotation will be provided prior to servicing at no charge.

  Before 

returning the unit, please consult a factory IMI applications engineer concerning the situation as certain problems 

can often be corrected with simple on-site procedures. 

 

Return procedure 

To expedite returned instrumentation, contact a factory IMI applications engineer for RETURN MATERIAL 

AUTHORIZATION (RMA) NUMBER.

  Please have information available such as model and serial number.  Also, 

to insure efficient service, 

provide a written description of the symptoms and problems with the equipment to a 

local sales representative or distributor, or contact IMI if none are located in your area. 

 

Customers outside the U.S. should consult their local IMI distributor for information on returning equipment.  For 

exceptions, please contact that International Sales department at IMI to request shipping instructions and an 

RMA.  For assistance, please call (716) 684-0003, or fax us at (716) 684-3823.  You may also receive assistance 

via e-mail at 

[email protected]

 or visit our website at 

www.pcb.com

 

Customer Service 

IMI, a division of PCB Piezotronics, guarantees 

Total Customer Satisfaction

.  If, at any time, for any reason, you 

are not completely satisfied with any IMI product, IMI will repair, replace or exchange it at no charge.  You may 

also choose to have your purchase price refunded. 

 

IMI offers to all customers, at no charge, 24-hour phone support.  This service makes product or application 

support available to our customers, day or night, seven days a week.  When unforeseen problems or emergency 

situations arise, call the 

IMI Hot Line at (716) 684-0003

, and an application specialist will assist you.

 

Summary of Contents for IMI SENSORS 646B10

Page 1: ...ometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail i...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...trial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL NUMBER 2531...

Page 7: ...n and Wiring Page 5 Standard Wiring Taking Measurements RV Option RVVO Option TO Option Installation Page 9 Direct Adhesive Mount Standard Stud Mount Adhesive Stud Mount Magnetic Mount ESD Sensitivity...

Page 8: ...further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Velocity Allows for continuous vibration m...

Page 9: ...PAGE 4 Dimension Drawing...

Page 10: ...ply to Pin B or Blue Wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter and or load resistor in line w...

Page 11: ...pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 641BX0 641BX1 641BX2 4 00 0 0 ips rms 0 0 ips rms 0 0 ips rms 8 00 0...

Page 12: ...option which integrates the signal to a value of 100 mV IPS 20 Figure 3 RV and RVVO wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV and RVVO negativ...

Page 13: ...e environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4 20mA Vibration Negative GREE...

Page 14: ...e 645 646 series because of the increased frequency response Direct Adhesive Mount Procedure For restrictions of space or for convenience most sensors with the exception of integral stud models can be...

Page 15: ...to properly prepare the machine surface consider using an adhesive mounting pad as a possible alternative Inspect the area checking that there are no burrs or other foreign particles interfering with...

Page 16: ...requency response This method involves attaching a base to the machine surface then securing the snesor to the base This alows for easy removal of the accelerometer STEP 1 Prepare a smooth flat mounti...

Page 17: ...adhere a stell mounting pad to the test surface This provides a smooth and repeatable location for mounting Figure 9 magnet types STEP 1 After choosing the correct magnet type inspect the unit verifyi...

Page 18: ...rical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug Any movement through air Th...

Page 19: ...ATION RMA NUMBER Please have information available such as model and serial number Also to insure efficient service provide a written description of the symptoms and problems with the equipment to a l...

Page 20: ......

Page 21: ......

Reviews: