Model Number
607A11
PLATINUM SWIVELER
®
INDUSTRIAL ICP® ACCELEROMETER
Revision H
ECN #: 26068
Performance ENGLISH
SI
Sensitivity (±15 %)
100 mV/g
10.2 mV/(m/s²)
[2]
Measurement Range
±50 g
±490 m/s
2
Frequency Range (±3 dB)
30 to 600000 cpm
0.5 to 10000 Hz
Resonant Frequency
1500 kcpm
25 kHz
[1]
Broadband Resolution (1 to 10000 Hz)
350 µg
3434 µm/sec
2
[1]
Non-Linearity
±1 %
±1 %
[3]
Transverse Sensitivity
≤
7 %
≤
7 %
Environmental
Overload Limit (Shock)
5000 g pk
49050 m/s² pk
Temperature Range
-65 to +250 °F
-54 to +121 °C
Enclosure Rating
IP68
IP68
Electrical
Settling Time (within 1% of bias)
≤
2 sec
≤
2 sec
Discharge Time Constant
≥
0.3 sec
≥
0.3 sec
Excitation Voltage
18 to 28 VDC
18 to 28 VDC
Constant Current Excitation
2 to 20 mA
2 to 20 mA
Output Impedance
<150 Ohm
<150 Ohm
Output Bias Voltage
8 to 12 VDC
8 to 12 VDC
Spectral Noise (10 Hz)
8 µg/
√
Hz 78.5
(µm/sec
2
/
√
Hz
[1]
Spectral Noise (100 Hz)
5 µg/
√
Hz 49.1
(µm/sec
2
/
√
Hz
[1]
Spectral Noise (1 kHz)
4 µg/
√
Hz 39.2
(µm/sec
2
/
√
Hz
[1]
Electrical Isolation (Case)
>10
8
Ohm >10
8
Ohm
Physical
Size (Hex x Height)
9/16 in x 0.97 in
14 mm x 24.6 mm
Weight (without cable)
1.1 oz
31 gm
[4]
Mounting
Stud
Stud
Mounting Thread
1/4-28 Male
Not Applicable
[5]
Mounting Torque (stud)
7 to 8 ft-lb
9.5 to 10.8 Nm
[6][7]
Mounting Torque (hex nut)
2 to 5 ft-lb
2.7 to 6.8 Nm
Sensing Element
Ceramic
Ceramic
Sensing Geometry
Shear
Shear
Housing Material
Stainless Steel
Stainless Steel
Sealing
Welded Hermetic
Welded Hermetic
Electrical Connector
Molded Integral
Cable
Molded Integral
Cable
Electrical Connection Position
Side
Side
Cable Length
10 ft
3.0 m
Cable Type
Polyurethane
Polyurethane
[8]
[9]
Optional Versions
(Optional versions have identical specifications and accessories as listed
for standard model except where noted below. More than one option maybe used.)
EX
- Hazardous Area Approval- contact factory for specific approvals
Hazardous Area Approval
Exia IIC T4, AExia
IIC, T4
Exia IIC T4, AExia
IIC, T4
Hazardous Area Approval
EEx nL IIC T4, -
40°C
≤
Ta
≤
121°C, II
1 G
EEx nL IIC T4, -
40°C
≤
Ta
≤
121°C, II
1 G
Hazardous Area Approval
Cl I, Div I, Groups
A, B, C, D; Cl II,
Div I, Groups E, F,
G; Cl III, Div I
Cl I, Div I, Groups
A, B, C, D; Cl II,
Div I, Groups E, F,
G; Cl III, Div I
Hazardous Area Approval
Cl I, Div 2, Groups
A, B, C, D; ExnL
IIC T4, AExnA IIC
T4
Cl I, Div 2, Groups
A, B, C, D; ExnL
IIC T4, AExnA IIC
T4
Hazardous Area Approval
EEx nL IIC T4, -
40°C
≤
Ta
≤
121°C, II
3 G
EEx nL IIC T4, -
40°C
≤
Ta
≤
121°C, II
3 G
M
- Metric Mount
Supplied Accessory: Model M080A159 Mounting stud, 1/2-20 to M6x1 (for Models
M607A11and M607A61) replaces Model 080A156
TO
- Temperature Output
Temperature Output Range
+36 to +250 °F
+2 to +121 °C
Temperature Scale Factor
5.56 mV/°F + 32
(+10 mV/°C)
Electrical Connector
Molded Integral
Cable
Molded Integral
Cable
Electrical Connections (Red)
Acceleration
Output
Acceleration
Output
Electrical Connections (Black) Ground Ground
Electrical Connections (White)
Temperature
Output
Temperature
Output
Notes
[1] Typical.
[2] Conversion Factor 1g = 9.81 m/s².
[3] Zero-based, least-squares, straight line method.
[4] Measured with mounting stud.
[5] 1/4-28 has no equivalent in S.I. units.
[6] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[7] 1/8" hex Allen key required for English version, 4 mm hex Allen key required for
Metric version.
[8] Twisted shielded pair.
[9] See PCB Declaration of Conformance PS023 or PS060 for details.
Supplied Accessories
080A156 Mounting Base (1)
ICS-2 NIST-traceable single-axis single-point amplitude response calibration at 6000 cpm
(100 Hz) (1)
Entered: LLH
Engineer: JEC
Sales: EGY
Approved: NJF
Spec Number:
Date:
03/20/2007
Date:
03/21/2007
Date:
03/21/2007
Date:
03/21/2007
12650