Model Number
607A11
PLATINUM SWIVELER® INDUSTRIAL ICP® ACCELEROMETER
Revision: J
ECN #: 41189
Performance
ENGLISH
SI
Sensitivity(± 15 %)
100 mV/g
10.2 mV/(m/s²)
[2]
Measurement Range
± 50 g
± 490 m/s²
Frequency Range(± 3 dB)
30 to 600,000 cpm
0.5 to 10,000 Hz
Resonant Frequency
1500 kcpm
25 kHz
[1]
Broadband Resolution(1 to 10,000 Hz)
350 µg
3434 µm/sec
2
[1]
Non-Linearity
± 1 %
± 1 %
[3]
Transverse Sensitivity
≤
7 %
≤
7 %
Environmental
Overload Limit(Shock)
5000 g pk
49,050 m/s² pk
Temperature Range
-65 to +250 °F
-54 to +121 °C
Enclosure Rating
IP68
IP68
Electrical
Settling Time(within 1% of bias)
≤
2 sec
≤
2 sec
Discharge Time Constant
≥
0.3 sec
≥
0.3 sec
Excitation Voltage
18 to 28 VDC
18 to 28 VDC
Constant Current Excitation
2 to 20 mA
2 to 20 mA
Output Impedance
<150 Ohm
<150 Ohm
Output Bias Voltage
8 to 12 VDC
8 to 12 VDC
Spectral Noise(10 Hz)
8 µg/
√
Hz
78.5 (µm/sec
2
)/
√
Hz
[1]
Spectral Noise
(100 Hz)
5 µg/
√
Hz
49.1 (µm/sec
2
)/
√
Hz
[1]
Spectral Noise
(1 kHz)
4 µg/
√
Hz
39.2 (µm/sec
2
)/
√
Hz
[1]
Electrical Isolation(Case)
>10
8
Ohm
>10
8
Ohm
Physical
Size (Hex x Height)
9/16 in x 0.97 in
14 mm x 24.6 mm
Weight(without cable)
1.1 oz
31 gm
[4]
Mounting
Stud
Stud
Mounting Thread
1/4-28 Male
1/4-28 Male
[5]
Mounting Torque(stud)
3 to 4 ft-lb
4.1 to 5.4 Nm
[6][7]
Mounting Torque
(hex nut)
2 to 3 ft-lb
2.7 to 4.1 Nm
Sensing Element
Ceramic
Ceramic
Sensing Geometry
Shear
Shear
Housing Material
Stainless Steel
Stainless Steel
Sealing
Welded Hermetic
Welded Hermetic
Electrical Connector
Molded Integral Cable
Molded Integral Cable
Electrical Connection Position
Side
Side
Cable Length
10 ft
3.0 m
Cable Type
Polyurethane
Polyurethane
[8]
[9]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
EX
- Hazardous Area Approval- contact factory for specific approvals
Hazardous Area Approval
Exia IIC T4, AExia IIC, T4
Exia IIC T4, AExia IIC, T4
Hazardous Area Approval
EEx nL IIC T4, -40°
C
≤
Ta
≤
121°C, II 1 G
EEx nL IIC T4, -40°
C
≤
Ta
≤
121°C, II 1 G
Hazardous Area Approval
Cl I, Div I, Groups A, B, C, D;
Cl II, Div I, Groups E, F, G; Cl
III, Div I
Cl I, Div I, Groups A, B, C, D;
Cl II, Div I, Groups E, F, G; Cl
III, Div I
Hazardous Area Approval
Cl I, Div 2, Groups A, B, C, D;
ExnL IIC T4, AExnA IIC T4
Cl I, Div 2, Groups A, B, C, D;
ExnL IIC T4, AExnA IIC T4
Hazardous Area Approval
EEx nL IIC T4, -40°
C
≤
Ta
≤
121°C, II 3 G
EEx nL IIC T4, -40°
C
≤
Ta
≤
121°C, II 3 G
M
- Metric Mount
Supplied Accessory : Model M080A159A Mounting stud, 1/2-20 to M6 x 1 (1)
TO
- Temperature Output
Temperature Output Range
+36 to +250 °F
+2 to +121 °C
Temperature Scale Factor
5.56 mV/°F + 32
+10 mV/°C
Electrical Connector
Molded Integral Cable
Molded Integral Cable
Electrical Connections(Red)
Acceleration Output
Acceleration Output
Electrical Connections
(Black)
Ground
Ground
Electrical Connections
(White)
Temperature Output
Temperature Output
NOTES:
[1] Typical.
[2] Conversion Factor 1g = 9.81 m/s².
[3] Zero-based, least-squares, straight line method.
[4] Measured with mounting stud.
[5] 1/4-28 has no equivalent in S.I. units.
[6] 1/8" hex Allen key required for English version, 3mm hex Allen key required for metric
version.
[7] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[8] Twisted shielded pair.
[9] See PCB Declaration of Conformance PS023 or PS060 for details.
SUPPLIED ACCESSORIES:
Model 080A156 Mounting Base (1)
Model ICS-2 NIST-traceable single-axis single-point amplitude response calibration at 6000
cpm (100 Hz) (1)
Entered: AP
Engineer: jg
Sales: EGY
Approved: BAM
Spec Number:
Date: 4/11/2013
Date: 4/11/2013
Date: 4/11/2013
Date: 4/11/2013
12650
3425 Walden Avenue, Depew, NY 14043
Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: [email protected]