PCB Piezotronics ICP 103B11 Installation And Operating Manual Download Page 3

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

CAUTION 

Refers to hazards that could damage 
the instrument.  

 

 

 

NOTE  

Indicates tips, recommendations and 
important information. The notes 
simplify processes and contain 
additional information on particular 
operating steps.  

 

The following symbols may be found on the equipment 
described in this manual: 

 

 

This symbol on the unit indicates that 
high voltage may be present.  Use 
standard safety precautions to avoid 
personal contact with this voltage.

 

 

 

This symbol on the unit indicates that 
the user should refer to the operating 
instructions located in the manual. 

 

 

This symbol indicates safety, earth 
ground.

 

 

 
 
 
 
 
 
 
 

 
 
 

 

 

Summary of Contents for ICP 103B11

Page 1: ...ure Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...igh sensitivity Models 103A02 and 103A12 ICP Sound Pressure Sensors 2 0 DESCRIPTION Refer to installation drawing no 103 1010 90 included as part of this manual The 103A Series Sensors utilize a bimor...

Page 7: ...2 since the radial wire leads of the Model 103A and 103A11 would interfere with the clamp nut The installation drawing gives detailed instructions on preparation of the port for this type of installat...

Page 8: ...pled signal conditioner such as the Model 484B Consult factory for details 5 0 CALIBRATION The 103A Series Sensors must be dynamically calibrated using a known step function or pulse or with a microph...

Page 9: ...hragm 316L Stainless Steel 316L Stainless Steel Sealing Epoxy Epoxy Electrical Connector Integral Cable Integral Cable Cable Termination Pigtail Ends Pigtail Ends Weight 0 115 oz 3 260 gm Cable Type 3...

Page 10: ...15 24 300 7 62 250 6 35 250 6 35 279 7 09 375 9 53 INSTALLED WITHOUT O RING PRESSURE SENSOR 4 40 X 43 10 9 LG CAP SCREW W LOCK WASHER 2 SUPPLIED MODEL 061A04 CLAMP ST STL 2 SUPPLIED 089 200 4 40 UNC 2...

Reviews: