background image

1

1

2

2

A

A

B

B

CODE

IDENT. NO.

52681

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

ANGLES

  

 

2 DEGREES

3425 WALDEN AVE. DEPEW, NY 14043

(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

ANGLES

  

 

2 DEGREES

FILLETS AND RADII 

 .003 - .005 

FILLETS AND RADII 

0.07 - 0.13 

OUTLINE DRAWING

58209

1 OF 1

1.5X

1/2" ICP MICROPHONE SYSTEM

 

DECIMALS     XX   ±.03

XXX   ±.010

DECIMALS    X   ± 0.8

XX   ± 0.25

BB

6/30/15

ECB

6/30/15

NJL

6/30/15

58

20

9

PCB Piezotronics Inc. claims proprietary rights in

the information disclosed hereon.  Neither it nor any

reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.

REVISIONS

REV

DESCRIPTION

DIN

NR

RELEASED TO DRAFTING

44281

3.30 [83.7]

.50 [12.7]

3.74 [95.0]

.52 [13.2]

MICROPHONE CARTRIDGE

.68 [17.1]

.50 [12.7]

PREAMPLIFIER

.03 [.8]

BNC CONNECTOR (OUTPUT)

Summary of Contents for HT378A06

Page 1: ...System Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...in which the instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument St...

Page 7: ...owered with a 24V or a 12V phantom power supply but this will limit the maximum output voltage Externally Polarized Microphone System Prepolarized Microphone System Phantom Powered Microphone System T...

Page 8: ...em such as the preamplifier signal conditioner or instrumentation Conversely the Cartridge Thermal Noise CTN specification provides the lowest measurable sound pressure level that can be detected abov...

Page 9: ...rugged grid cap shown below and as an independent part of a rugged kit to extend the lifespan of the precision measuring device caution should be taken to ensure the delicate diaphragm sensing element...

Page 10: ...ustry standards ensures accurate calibra tion against relevant specifications We also carry a line of acoustic calibrators that can be used to calibrate microphone sensitivity on site as needed Hand c...

Page 11: ...to14 VDC Maximum Output Voltage 7 Vpk 7 Vpk Output Impedance 50 Ohm 50 Ohm Physical HousingMaterial Stainless Alloy Stainless Alloy Venting Rear Rear 5 Electrical Connector BNC Jack BNC Jack MountingT...

Page 12: ...07 0 13 OUTLINE DRAWING 58209 1 OF 1 1 5X 1 2 ICP MICROPHONE SYSTEM DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 BB 6 30 15 ECB 6 30 15 NJL 6 30 15 58209 PCB Piezotronics Inc claims proprietary right...