S12: 

 

Off = 0-5Vdc Output, On = 0-10Vdc Output 

Internal DIP Switch Setting 
 

The Internal DIP Switch of the 

682 Series 

must be configured for the Full Scale Output of the ICP

®

 Sensor 

connected to it. This is accomplished by removing the front cover and sliding the PC Board out of the Signal 
Conditioner. Once removed, the DIP switch should be configured per one of the conditions in the following table.  
 

Range Setting 

S1 

S2 

S3 

S4 

S5 

S6 

S7 

S8 

S9 

S10 

S11 

5g RMS 

ON 

ON 

OFF 

OFF

 

OFF 

OFF

 

ON 

OFF 

OFF

 

OFF

 

ON 

5g Peak 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

OFF 

ON 

OFF

 

OFF

 

ON 

10g RMS 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

ON 

OFF 

OFF

 

ON 

OFF

 

10g Peak 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

OFF 

ON 

OFF

 

ON 

OFF

 

20g RMS 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

ON 

OFF 

ON 

OFF

 

OFF

 

20g Peak 

ON 

ON

 

OFF 

OFF

 

OFF 

OFF

 

OFF 

ON 

ON 

OFF

 

OFF

 

0.5 in/sec RMS 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

ON 

OFF 

OFF

 

OFF

 

ON 

0.5 in/sec Peak 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

OFF 

ON 

OFF

 

OFF

 

ON 

1.0 in/sec RMS 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

ON 

OFF 

OFF

 

ON 

OFF

 

1.0 in/sec Peak 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

OFF 

ON 

OFF

 

ON 

OFF

 

2.0 in/sec RMS 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

ON 

OFF 

ON 

OFF

 

OFF

 

2.0 in/sec Peak 

OFF 

OFF

 

ON 

ON

 

OFF 

OFF

 

OFF

 

ON 

ON 

OFF

 

OFF

 

10 mils p-p 

OFF 

OFF

 

OFF 

OFF

 

ON 

ON

 

OFF

 

OFF

 

OFF

 

OFF

 

ON 

20 mils p-p 

OFF 

OFF

 

OFF 

OFF

 

ON 

ON

 

OFF

 

OFF

 

OFF

 

ON 

OFF

 

40 mils p-p 

OFF 

OFF

 

OFF 

OFF

 

ON 

ON

 

OFF

 

OFF

 

ON 

OFF 

OFF

 

                                                                   

S12 

OFF 

0-5Vdc Output 

S12 

ON 

0-10Vdc Output 

 

Note: Factory Default Setting is 1.0in/sec Peak, 0-5Vdc Output 

 
 

 
 
Filter Module Location

 

 

The Filter Modules are utilized to set the cutoff frequency of the internal band pass filter circuit. The 

682 Series 

comes standard with Modules preinstalled. If a different cutoff frequency is desired, the preinstalled module can 
be removed by simply pulling it out of the MOD socket, and replacing it with a different module. The module is 
labeled with the type of filter, Low Pass or High Pass, and the cutoff frequency. Module location is as follows: 
 

MOD1:   

Low Pass (LP) Filter Module Location 

MOD2:   

High Pass (HP) Filter Module Location 

 

 
 
 
 

Warning:

 Do not make any adjustments to the internal potentiometers. These potentiometers are used for 

factory calibration and adjusting them will require return of the 

682 Series unit

 to the factory for recalibration. 

 
 
 
 

Summary of Contents for 682B03

Page 1: ...itter Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail im...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...Series 4 20mA Din Rail ICP Signal Conditioner Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800...

Page 5: ...ORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 6 Configuring the 682BX3 Page 10 ESD Sensitivity Page 13 Ordering Information Page 14 Warranty Servicing Warra...

Page 6: ...oner Optional 500Vdc Input to Output Electrical Isolation Selectable 24Vdc Unregulated 18Vdc regulated 4mA excitation to power sensor 4 20mA Output Signals for Vibration and Temperature Selectable 0 5...

Page 7: ...stallation The 682 Series is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils IMI Sensors recommends mounting the 682...

Page 8: ...closure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devic...

Page 9: ...7 to 8 Pin 7 Temperature Sensor Pin 8 Temperature Sensor ICP Accelerometer Raw Vibration RV Pins 9 to 10 and BNC Jack Pin 9 RV Pin 10 RV 4 to 20mA Temperature Output Pins 11 to 12 Pin 11 4 to 20mA Te...

Page 10: ...D INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram To Maintain Conformance Earth Ground Power Supply Common and I O Shields must be connected together 682 Series Signal Conditio...

Page 11: ...gnal conditioner for various sensor and vibration ranges The Filter Modules are installed to set the High and Low cutoff frequencies The Jumper selects unregulated regulated or no ICP power to the acc...

Page 12: ...FF OFF ON ON OFF OFF OFF ON OFF ON OFF 2 0 in sec RMS OFF OFF ON ON OFF OFF ON OFF ON OFF OFF 2 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON ON OFF OFF 10 mils p p OFF OFF OFF OFF ON ON OFF OFF OFF OFF...

Page 13: ...PAGE 10 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Sensor Power Jumper Configuration 682 Series Signal Conditioner...

Page 14: ...ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer...

Page 15: ...682A X 3 Frequency Response Isolation 0 3Hz to 10kHz Standard 1 3Hz to 1kHz 2 10Hz to 10kHz 3 10Hz to 1kHz 4 3Hz to 10kHz with 500Vdc I O Isolation 5 3Hz to 1kHz with 500Vdc I O Isolation 6 10Hz to 1...

Page 16: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Page 17: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 18: ...r maximum 100 mA 100 mA Settling Time 2 min 2 min Excitation Voltage delivered to sensor 17 to 19 VDC 17 to 19 VDC 1 2 Constant Current Excitation delivered to sensor 3 to 5 mA 3 to 5 mA 1 2 Output Sp...

Page 19: ...Fault Red LED Red LED Status Indicator Measurement Mode Acceleration Green LED Green LED Status Indicator Measurement Mode Velocity Green LED Green LED Status Indicator Measurement Mode Displacement...

Page 20: ......

Reviews: