The 422E series in-line charge converters are designed to convert the high impedance of a charge 

mode piezoelectric transducer to a low-impedance voltage by means of an ICP ® signal conditioner.  

These units may be used with either quartz or ceramic charge-mode piezoelectric sensors. 

 

 

description 

 

The 422E series in-line charge amplifiers operate from an ICP ® signal conditioner.  The unit employs a 

high gain amplifier to perform the impedance transformation.  The charge output of the transducers 

may be scaled in terms of acceleration, pressure or force.  The output is then mV/g, mV/psi or mV/lb, 

respectively.   

 

 

installation 

 

Connect the 422E series to the transducer with low-noise cable (003A) only.  Standard coaxial or two-

wire cable may be used between the amplifier and the signal conditioner, and between the signal 

conditioner and the readout device. 

 

Note:  For optimum noise performance, the cable length between the sensor and the 422E should be 

minimized. 

 

operation 

 

To operate, simply connect the input of the 422E to the transducer using low-noise (003A) cable and 

the output to any ICP ® signal conditioner using standard cable.  The output of the signal conditioner 

may then be connected to an oscilloscope or other monitoring device.  This output will be an AC signal 

(see 

specification

 for actual frequency response) with a DC bias.  Many PCB signal conditioners 

remove the bias via an AC coupling circuit. 

 

 

PAGE 3 

 

N

Summary of Contents for 422E

Page 1: ...onverter Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...arranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0001 Fax 716 684 0987 E Mail electronics pcb com Toll Free Line 1 800 828 8840 24 Hour Sensor Line 716 684 0001 RATION AC...

Page 7: ...nstallation page 3 Operation page 3 Calculation of Output Scaling page 4 TEDS Functionality page 4 Special Considerations page 5 422E Series Models for Use with High Temperature Sensors page 5 422E Se...

Page 8: ...essure or force The output is then mV g mV psi or mV lb respectively installation Connect the 422E series to the transducer with low noise cable 003A only Standard coaxial or two wire cable may be use...

Page 9: ...r Sensitivity pC Engineering Unit where Vout Output of 422E in mV Engineering Unit the Engineering Unit may be g s Newtons psi etc depending on the sensor Example A 357A12 3 pC g is used with a 422E02...

Page 10: ...se cable is used these values correspond to 10 meters and 100 meters of length respectively 422E series models for use with high temperature sensors The 422E35 1 mV pC and 422E36 10 mV pC have been sp...

Page 11: ...for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid injury warning 2 ESD sensitivity This equipment is designed with user safety i...

Page 12: ...local sales contact or distributor Batteries and other expendable hardware items are not covered by warranty service Because of the sophisticated nature of PCB instrumentation field repair is typicall...

Page 13: ...d PCB offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems or...

Page 14: ......

Page 15: ......

Reviews: