The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual.

 

 

Total Customer Satisfaction

 – PCB 

Piezotronics guarantees Total Customer 
Satisfaction. If, at any time, for any 
reason, you are not completely satisfied 
with any PCB product, PCB will repair, 
replace, or exchange it at no charge. You 
may also choose to have your purchase 
price refunded in lieu of the repair, 
replacement, or exchange of the product. 
 

Service

 – Due to the sophisticated nature 

of the sensors and associated 
instrumentation provided by PCB 
Piezotronics, user servicing or repair is 
not recommended and, if attempted, may 
void the factory warranty. Routine 
maintenance, such as the cleaning of 
electrical connectors, housings, and 
mounting surfaces with solutions and 
techniques that will not harm the 
physical material of construction, is 
acceptable. Caution should be observed 
to insure that liquids are not permitted to 
migrate into devices that are not 
hermetically sealed. Such devices should 
only be wiped with a dampened cloth 
and never submerged or have liquids 
poured upon them. 
 

Repair

 – In the event that equipment 

becomes damaged or ceases to operate, 
arrangements should be made to return 
the equipment to PCB Piezotronics for 
repair. User servicing or repair is not 
recommended and, if attempted, may 
void the factory warranty. 
 

Calibration

 – Routine calibration of 

sensors and associated instrumentation is 

recommended as this helps build 
confidence in measurement accuracy and 
acquired data. Equipment calibration 
cycles are typically established by the 
users own quality regimen. When in 
doubt about a calibration cycle, a good 
“rule of thumb” is to recalibrate on an 
annual basis. It is also good practice to 
recalibrate after exposure to any severe 
temperature extreme, shock, load, or 
other environmental influence, or prior 
to any critical test. 
 
PCB Piezotronics maintains an ISO-
9001 certified metrology laboratory and 
offers calibration services, which are 
accredited by A2LA to ISO/IEC 17025, 
with full traceablility to N.I.S.T. In 
addition to the normally supplied 
calibration, special testing is also 
available, such as: sensitivity at elevated 
or cryogenic temperatures, phase 
response, extended high or low 
frequency response, extended range, leak 
testing, hydrostatic pressure testing, and 
others. For information on standard 
recalibration services or special testing, 
contact your local PCB Piezotronics 
distributor, sales representative, or 
factory customer service representative. 
 

Returning Equipment

 – 

Following 

these procedures will insure that your 
returned materials are handled in the 
most expedient manner

. Before returning 

any equipment to PCB Piezotronics, 
contact your local distributor, sales 
representative, or factory customer 
service representative to obtain a Return 

Warranty, Service, Repair, and 

Return Policies and Instructions 

Summary of Contents for 377B02

Page 1: ...Microphone Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E m...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...he instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument Standards th...

Page 5: ...ponse reactions of the human ear to the pressure fluctuations Some examples of typical sound pressure levels are shown in the table below dB Pressure Example 0 0 00002 Pa Threshold of Hearing 60 0 02...

Page 6: ...and noise cones the fre quency response of the microphone will be attenuated at higher frequencies Clamps and stands When holding a microphone in place it is important to minimize the influence of the...

Page 7: ...2LA manufacturers Our internal metrology laboratory is certified to ISO 9001 accredited by A2LA to AN SI IEC 17025 and ANSI NCSL Z540 1 complies with ISO 10012 1 and former MIL STD 45662A and uses equ...

Page 8: ...dB re 20 Pa 63 dB re 20 Pa 1 Long Term Stability 150 C 302 F 2 hrs dB 2 hrs dB Electrical Capacitance Polarized 12 pF 12 pF 1 Polarization Voltage 0 V 0 V 2 Physical Housing Material Stainless Alloy S...

Page 9: ...ARIZED MICROPHONES DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JDM 9 14 05 ECB 9 14 05 CCL 9 14 05 1 1 2 2 A A B B 60 15 3 64 16 4 36 9 2 50 12 7 4606 60 UNS 11 7 mm 60 UNS THREADS 52 13 2 47 12 0 4...

Reviews: