Sensitivity(± 50 %)(at 10 VDC excitation)
0.20 mV/g
0.02 mV/(m/s²)
[1]
Sensitivity
0.02 mV/V/g
0.002 mV/V/(m/s²)
[7]
Measurement Range
± 2000 g
± 19,620 m/s² pk
Frequency Range(± 1 dB)
0 to 10,000 Hz
0 to 10,000 Hz
Resonant Frequency
>20 kHz
>20 kHz
Damping Ratio
0.7 % Critical
0.7 % Critical
[5]
Non-Linearity
± 1 %
± 1 %
Transverse Sensitivity
≤
3 %
≤
3 %
Environmental
Overload Limit(Shock)
± 10,000 g pk
± 98,100 m/s² pk
[4]
Overload Limit
(Mechanical Stops)
≥
2000 g
≥
19,620 m/s² pk
Temperature Range(Storage)
-65 to 250 °F
-54 to 121 °C
Temperature Range
(Operating)
-65 to 250 °F
-54 to 121 °C
Temperature Coefficient of Sensitivity
-0.11 %/°F
-0.20 %/°C
[5]
Zero g Offset Temperature Shift
± 20 mV
± 20 mV
[6]
Base Strain Sensitivity
0.3 g/µ
ε
2.94 (m/s²)/µ
ε
[5]
Electrical
Excitation Voltage(Maximum)
15.0 VDC
15.0 VDC
Current Consumption
<10 mA
<10 mA
Input Resistance(± 1250 Ohm)
2750 Ohm
2750 Ohm
[1]
Output Resistance(± 1250 Ohm)
2750 Ohm
2750 Ohm
[1]
Offset Voltage
-40 to +40 mVDC
-40 to +40 mVDC
[1]
Settling Time
0.01 sec
0.01 sec
[2]
Electrical Isolation(Case)
≥
10
8
Ohm
≥
10
8
Ohm
[3]
Physical
Sensing Element
Piezoresistive MEMS
Piezoresistive MEMS
Sensing Geometry
Full Active
Full Active
Housing Material
Titanium
Titanium
Sealing
Epoxy
Epoxy
Size (Hex x Height)
3/8 in x .50 in
3/8 in x 12.7 mm
Weight(without cable)
0.088 oz
2.5 gm
[5]
Electrical Connector
Integral Cable
Integral Cable
Electrical Connection Position
Side
Side
Cable Type
034 4-cond Shielded
034 4-cond Shielded
Cable Termination
Pigtail Ends
Pigtail Ends
Cable Length
10 ft
3.05 m
Mounting
Integral Stud
Integral Stud
Mounting Thread
1/4-28 Male
1/4-28 Male
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
ICP
®
is a registered trademark of PCB Group, Inc.
M
- Metric Mount
Mounting Thread
M6 x 0.75 Male
M6 x 0.75 Male
NOTES:
[1]Verified with test data provided on supplied calibration certificate.
[2]Settling Time is the maximum time after power-up for the Offset Voltage to be /-2% of
Measurement Range output of the final offset value. Mounting surface must be at thermal
equilibrium.
[3]Individually tested to ensure compliance with specified value.
[4]Half-sine pulse duration,
≥
20 µsec.
[5]Typical.
[6]-65 to +250 °F, ref. 75 °F (-54 to +121 °C, ref. 24 °C)
[7]Sensitivity is proportional to excitation voltage, and at other excitation values, sensitivity can be
predicted from the 10VDC calibrated value with a small (<~.5%) increase in uncertainty.
SUPPLIED ACCESSORIES:
Model ACS-62 Shock Calibration of Piezoresistive High Amplitude Accelerometers
3425 Walden Avenue, Depew, NY 14043
Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]
OPTIONAL VERSIONS
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
Entered: JM
Engineer: MAM
Sales: RM
Approved: JJB
Spec Number:
Date: 8/26/2015
Date: 8/26/2015
Date: 8/26/2015
Date: 8/26/2015
56778