Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

[email protected]

 

Repair inquiries

[email protected]

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for 112B05

Page 1: ...e Sensor Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...that the sensor is supplied with optional features A option Ablative thermal barrier E option Emralon coating H option Hermetic seal J option Electrical isolation mounting adaptor required M option Me...

Page 7: ...ies 113A High Frequency Miniature Sensor The Series 113A High Frequency Miniature Sensor is a charge mode pressure sensor designed to measure shock wave blast explosion ultrasonic and dynamic combusti...

Page 8: ...rage pressure level over a wide amplitude range and a usable frequency range near DC to between 5 000 and 10 000 Hz the resonant frequency is 25 000 Hz The Model 171 is extremely sensitive with a nomi...

Page 9: ...nd L length of column feet For air at room temperature the equation becomes L 3300 Fr Where L passage length inches The natural frequency and approximately fastest pressure step rise time for various...

Page 10: ...z element The clamp nut is provided with either standard 5 16 24 or metric M7 x 0 75 threads and is supplied along with three seal rings Model 008A Hardline Cable is recommended for operating temperat...

Page 11: ...nce charge signal generated by the sensor into a low impedance voltage signal This signal may then be transmitted to a readout or recording device for analysis See Figure 5 1 for a drawing of a typica...

Page 12: ...DC offset voltage usually very tiny microvolts that exists at the input gate of the MOSFET circuit This minute leakage current exists in all real devices As demonstrated in Equation 1 the steady state...

Page 13: ...1 Introduction 6 4 Low Frequency Response Limitations In a normal charge amplifier the low frequency response is set by the RC time constant as established by the product of Cf and Rf The system acts...

Page 14: ...umulated electrostatic charges may build to the point that they may saturate or even damage the input circuitry of the charge amplifier Operate the charge amplifier in the SHORT time constant while th...

Page 15: ...ure unless otherwise specified In the interest of constant product improvement we reserve the right tochange specifications without notice ICP is a registeredtrademarkof PCB Piezotronics Inc P Positiv...

Page 16: ...y reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc 1 56 39 6 81 20 6 34 8 5 235 5 97 248 6 30 218 001 000 5 52 03 00 REVISIONS REV DESCRIPTION DIN P...

Page 17: ...t nor any reproduction thereof will be disclosed to others without the written consent of PCB Piezotronics Inc 39 6 1 56 20 6 81 8 5 34 5 97 235 6 30 248 5 52 03 00 218 001 000 REVISIONS REV DESCRIPTI...

Reviews: