OPERATION MANUAL FOR 

ICP

 HIGH PRESSURE SENSOR 

Series 108B

 

 

 5 

Use a high pressure pump with dial reference gage or 
a  dead  weight  tester  to  apply  pressure  in  desired 
increments  to  full  scale.    Dump  pressure  after taking 
the  reading  and  before  proceeding to the next higher 
pressure level. 
 
With  a  2000  second  discharge  TC,  1%  of  the  signal 
will be lost in 20 seconds, so it is imperative that the 
pressure  setting  and  recording  of  output  be 
accomplished quickly. 
 
A  calibration  graph  can  then  be  plotted  using  output 
voltage vs. input pressure. 

5.0 

OPERATION

 

 
Select  desired  mode  of  circuit  connection  and  turn 
power  unit  on.    Observe  fault  monitor  meter  at  the 
front panel of the power unit. 
 
Normal  operation  is  indicated  by  an  approximate 
midscale  reading.    Shorted  cable  or  connections  are 
indicated by a zero reading (red area).  Open cable or 
connections are indicated by a full-scale (yellow area) 
reading. 
 
Allow  instrument  several  minutes  to  warm  up  and 
thermally stabilize. 
 
When output from power unit is connected to readout 
equipment,  a  drifting  of  the  voltage  signal  will  be 
noticed.  This is normal.  It is due to the charging of 
the  coupling  capacitor  in  the  power  unit  and  will 
cease within several minutes. 

 
6.0 

POLARITY

 

 
The  series  108B  produces  a  positive-going  output 
voltage for increasing pressure at the diaphragm. 
 

7.0 

MAINTENANCE 

 

The  small  size  and  sealed  construction  of  the  series 
108B precludes field maintenance and repair. 

ICP is a registered trademark of PCB Piezotronics 

Summary of Contents for 108A02

Page 1: ...0k psi 0 5 mV psi long life Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...The 3 8 24 thread and flush diaphragm design are conventional providing direct interchangeability with existing welded diaphragm type piezoelectric sensors The simple rigid piezo element containing o...

Page 5: ...m tool chatter marks NOTE It is important that this surface be perfectly smooth and free from nicks or other discontinuities which might cause leaks at high pressures 3 3 RECESSED MOUNT The recessed i...

Page 6: ...nts sensor life may be severely limited with flush installation 3 5 FLASH TEMPERATURE EFFECTS The ceramic coating on the diaphragm of these sensors should render the flash thermal effect insignificant...

Page 7: ...ation to take full advantage of the sensor discharge time constant With this arrangement the readout is direct coupled to the sensor and the output signal will be added to the 11 volt Nom bias level T...

Page 8: ...rve fault monitor meter at the front panel of the power unit Normal operation is indicated by an approximate midscale reading Shorted cable or connections are indicated by a zero reading red area Open...

Page 9: ......

Page 10: ......

Reviews: