17
UMCC will automatic detect COM port from 1 to 15. And support Auto link COM port each device.
if device link fail, UMCC will show up below message
Please try again
,
if still got the link fail message
,
Please check the Device Manager the Silicon Lab CP210x
USB Device first
Each UART control 4 display port
,
for example 12 Port system should be have 3 devices.
Press Turn on Button the UMCC will check the Box ID first, if UMCC detect wrong device number or the
Box ID number
,
Please using “Identify” button to auto setting the Box ID
Pattern Off/On Button
:
Test Monitor Quality of each display
Test signal output automatically, UMCC will output different pattern signal, the test time can be set by
Setting button. The test will back to panel of ADM 4X Control Center after test is finished, and then Pattern
On turn to Off automatically. If without pattern signal output, it means the connection of output failed,
please check the connection
.
Automatic output difference test Pattern to monitor, the Pattern display time control by “ Setting” Button