8
Calibrating the Sprayer
Tip Size
PSI
GPM of one
nozzle
Gallons Per Acre (GPA)
2mph
3 MPH
4 MPH
5 MPH
6 MPH
TP11008VP
35
0.75
52.8
35.5
26.4
21.1
17.6
40
0.8
56.2
37.5
28.1
22.5
18.7
NOTE: Flow rates are calculated using water.
Boom Application Rate Chart
Tip Size
PSI
GPM of one
nozzle
Gallons per 1000 Sq. Ft
2mph
3 MPH
4 MPH
5 MPH
6 MPH
TP11008VP
35
0.75
1.21
0.80
0.60
0.48
0.40
40
0.8
1.29
0.86
0.64
0.51
0.43
The sprayer operates at a fixed pressure through the boom and spray wand. Although the pressure can be adjusted to the boom by
partially opening the boom control valve (1) (Figure 1, pg 9), it is recommended that the valve is operated in full open position. Use
the chart below to select your desired speed and application rate.
2. Application Rate Charts