EN
ENGLISH
Page -10-
PBU
Operator's Manual (EN) - DC Propane Burnisher
8 Hour Time Weighted Average (OSHA Method)
1.5 % 750,000cf
Hours Operation
1
2
3
4
5
6
7
8
TWA (OSHA Method)
0 change/hr
5
14
27
46
69
96
128 164
1/2 change/hr
4
9
16
24
33
42
50
59
1 change/hr
3
7
11
16
20
25
29
34
2 change/hr
2
4
7
9
11
13
16
18
Based on the CO production rates shown above the TWA would not be exceeded in a
100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour.
(Assumes no additional CO
exposure during 8 hour time period)
Maintenance of Equipment
Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on
engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes
fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as
well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator’s Manual that were
supplied with the equipment. Additional manuals may be obtained by contacting at 1-800-545-3454 or write to Customer
Service, 2100 Hwy. 265, Springdale AR 72764.
CO Safety Equipment Available
•
Envirogard automated fuel to air ratio monitoring and regulation providing an optimum combustion
•
Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine
exhaust providing the lowest possible emissions
•
High cubic feet per minute (CFM) fans (forced air mixing)
•
Digital combustion analyzers for tail pipe emissions monitoring
SPECIFICATIONS:
Model
Dust Control
2117BCATCL
2717BCATCL
Part Number
08992B
08993B
Pad Size
21" (53 cm)
27" (68 cm)
Engine
17 hp Twin-V Kawasaki
Catalytic Muffler
Yes
Carb Gard
Yes
Clutch
Centrifugal
Pad Speed
2100 RPM
1500 RPM
Propane Tank
20 lb. (9.1 kg) Capacity, 80% Safety fill
Auto Fuel Shutoff
Yes
Low Oil Shutdown
Yes
Hour Meter
Yes
Sound Level
87 - 89 dB(A)
Productivity Rate
25,000 ft
2
/hr (2,322 m
2
/hr)
33,000 ft
2
/hr (3,066 m
2
/hr)
Agency Approvals
EPA plus UL Approved Propane Components
CARB Certified
(California Air Resource Board)
Yes
Weight
276 lbs.
298 lbs.
Dimensions:
Length
66" (167.4 cm)
69" (175.3 cm)
Widith
23.5" (59.7 cm)
29.5" (74.9 cm)
Height
43" (109.2 cm)
43" (109.2 cm)
Warranty
2 Year Parts & Labor