- 10 - FORM NO. 71506A
PBU
Operator's Manual (EN) - Propane Stripper
EN
ENGLISH
8 Hour Time Weighted Average (OSHA Method)
1.5 % 750,000cf
Hours Operation
1
2
3
4
5
6
7
8
TWA (OSHA Method)
0 change/hr
5
14
27
46
69
96
128 164
1/2 change/hr
4
9
16
24
33
42
50
59
1 change/hr
3
7
11
16
20
25
29
34
2 change/hr
2
4
7
9
11
13
16
18
Based on the CO production rates shown above the TWA would not be exceeded in a
100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour.
(Assumes no additional CO
exposure during 8 hour time period)
Maintenance of Equipment
Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on
engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes
fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as
well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator’s Manual that were
supplied with the equipment.
CO Safety Equipment Available
•
Carb Guard automated emissions monitoring will shut down the engine when high emissions are detected.
•
Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine
exhaust providing the lowest possible emissions
•
High cubic feet per minute (CFM) fans (forced air mixing)
•
Digital combustion analyzers for tail pipe emissions monitoring
SPECIFICATIONS:
Model
2113 BCATCLCG ST
Part Number
08006B
Brush Size
21" (53 cm)
Engine
13 hp V-Twin Kawasaki
Catalytic Muffler
Yes
Carb Gard
Yes
Clutch
Centrifugal
Brush Speed
1400 RPM
Propane Tank
20 lb. (9.1 kg) Capacity, 80% Safety fill
Auto Fuel Shutoff
Yes
Low Oil Shutdown
Yes
Hour Meter
Yes
Sound Level
88 - 90 dB(A)
Agency Approvals
EPA plus UL Approved Propane Components
CARB Certified
Yes
(California Air Resource Board)
Weight
Dimensions:
Length
51.5" (131.8 cm)
Widith
23.3" (59 cm)
Height
43" (109.2 cm)
Warranty
2 Years Parts & Labor