2
SAP ORDERING NO.
CASING
DIMENSIONS (IN.)
RATED HEATING OUTPUT
{
(BTUH)
HEATING
COOLING
CFM @ 0.5
ESP
MOTOR HP
(VARIABLE
SPEED)
APPROX.
SHIP WT.
(LB)
H
D
W
High
Low
AFUE
CFM‡
(Low
Heating)
CFM
(High
Heating)
Rated
High
Heating
ESP
PG96VAT30040AA 35 29.5 14.2
39,000
25,000
96.0%
660
815
0.10
440 - 905
1/2
121
PG96VAT42060BA 35 29.5 17.5
58,000
38,000
96.0%
860
1135
0.12
435 - 1475
3/4
142
PG96VAT48080BA 35 29.5 17.5
78,000
50,000
96.0%
1160
1505
0.15
555 - 1610
3/4
152
PG96VAT60080CA 35 29.5 21.0
78,000
51,000
96.0%
1200
1555
0.15
440 - 2005
1
156
PG96VAT60100CA 35 29.5 21.0
97,000
63,000
96.0%
1435
1865
0.20
405 - 2005
1
166
PG96VAT66120DA 35 29.5 24.5 117,000
76,000
96.0%
1675
2375
0.20
480 - 2115
1
190
{
Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡
Minimum heat CFM when low---heat rise adjustment switch (SW 1---3) and comfort/efficiency adjustment switch (SW1---4) on control center are OFF.
ESP --- External Static Pressure
Dual Fuel System Compatibility
— This system can provide
more control over your monthly energy bills by automatically
selecting the most economical method of heating. Our system
automatically switches between the gas furnace and the electric
heat pump as outside temperatures change to maintain greater
efficiency and comfort than with any traditional single-source
heating system. The heat pump also delivers high-efficiency
cooling in the summer.
Robust Igniter
— Payne’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Payne’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
Reliable Heat Exchanger Desig
n — The aluminized steel, clam
shell primary heat exchanger was re--engineered to achieve greater
efficiency out of a smaller size. The first two passes of the heat
exchanger are based on the current 80% product, a design with
more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
4-Way Multipoise Design
— One model for all applications –
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting
,
or Optional Ventilated
Combustion Air
— This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.
Sealed Combustion System
— This furnace brings in combustion
air from outside the furnace when installed as a direct vent or
ventilated combustion air venting system, which results in
especially quiet operation. By sealing the entire combustion
vestibule, the entire furnace can be made quieter, not just the
burners.
Monoport Burners
— The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure
— Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch
— Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration
— Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications
— This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is AHRI efficiency rating certified. This furnace
meets California Air Quality Management District emission
requirements.
PG96V