![Paxton Switch2 Installation Manual Download Page 16](http://html1.mh-extra.com/html/paxton/switch2/switch2_installation-manual_1513401016.webp)
Chapter 4 Commissioning
TOUCHLOCK system
CARDLOCK & PROXIMITY system
PROXIMITY KP series keypad
TOUCHLOCK system
Initialising the system
After the system has been wired up, be sure to check over the connections against the
wiring diagrams provided before powering up for the first time. When the system is
powered up for the first time the control will bleep 3 times a second. This indicates that
Switch2 is waiting to be initialised. The
RED
LED will be on, the
AMBER
LED will flash
slowly and the
GREEN
LED will be flashing quickly.
•
Press the bell button
(The unit will stop bleeping and the
GREEN
LED flashes faster)
•
Enter your chosen 6 digit programming code* and press the bell button.
(The
GREEN
LED will flash faster still)
•
Confirm your chosen programming code by entering the same 6 digit code
and pressing the bell button.
(The
GREEN
LED goes out and the unit will acknowledge that the programming
code has been accepted by bleeping twice after a short pause. All LEDs are now on)
* Note that the programming code SHOULD NOT have the sequence of numbers
1234 in, as this is the default user code
What is the next step?
The keypad/s now has a default user code 1234. The programming code you just set will
let you into programming mode, where configuration changes can be made. The system
will work according to the default settings (See Operation – TOUCHLOCK).
Check the system operates correctly using the default settings.
•
Type in the user code 1234
(The
GREEN
LED will flash on the keypad/s and the relay will switch over for 7
seconds)
•
Type in the master code you set
(There will be 2 beeps to confirm that the correct master code has been entered
and the
GREEN
LED will flash)
Chapter 4 Commissioning
16