Paxton Proximity 345-110 Installation Manual Download Page 8

The declaration of conformity is available on request. Contact details are provided at:   

http://paxton.info/596

These products are not suitable for retail sale.  All warranties are invalid if these products are 

not installed by a competent person. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 

two conditions:

 (1) this device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation. Changes 

or modifications not expressly approved by the party responsible for compliance could void 

the user's authority to operate the equipment. 

To comply as a UL listed installation, the following conditions must apply:-

• 

Server based functions (Antipassback, Time and Attendance, etc) have not been 

evaluated by UL and cannot be used for UL 294 installations.

• 

Where an equivalent cable / wire is used it must be ‘ UL Listed ‘All interconnecting 

devices must be UL Listed.

• 

The use of Wiegand readers and the configuration software has not been evaluated 

by ‘UL’

• 

For CAN/ULC-S319 installations, terminals, leads and wiring methods must comply 

with CSA, C22.1, Canadian electrical code, Part 1, safety standards for electrical 

installations. 

• 

The use of any add-on, expansion, memory or other module manufactured or 

supplied by the manufacturer’s representative will invalidate the CAN/ULC-S319 

certification.

• 

Wiring methods shall be in accordance with the National Electrical Code (ANSI/

NFPA70), local codes, and the authorities having jurisdiction.

Product compliance and limitations 

North America:- 

This device complies with Industry Canada licence-exempt RSS standard(s). Operation is 

subject to the following two conditions: (1) this device may not cause interference, and (2) 

this device must accept any interference, including interference that may cause undesired 

operation of the device.

Classification for UL 294

FCC Compliance

1

1

4

3

Destructive attack

Line Security 

encryption

Endurance

Standby Power

7

Summary of Contents for Proximity 345-110

Page 1: ...Paxton ins 20600 Proximity readers and Keypads ...

Page 2: ...1 2 1 Mounting 1 ...

Page 3: ...oximity P and and keypad proximity KP readers should not be mounted on metal surfaces Screw connector option The unit should be mounted in conjunction with an electrical backbox to achieve the required clearance for the connector If an adaptor plate 310 750 is fitted the mountings on the backbox can also be used 2 ...

Page 4: ...r keypad are correct Connections Check the wiring and integrity of the connectors If possible test this reader on the other port Extended cable Belden 9538 9540 should be used up to a maximum of 500 feet Twisted pair alarm cable should not be used To confirm that an extended reader cable is not at fault wire the reader directly to the port Supply voltage Confirm that the voltage is within specific...

Page 5: ...hen you present a blank or existing token to that reader it will allow you to add this new token or edit the existing one NOTE Remember to return the operating mode to the original setting once the cards have been read or users will not be able to gain access through the reader KP Reader Ensure that Keypad type is set to None otherwise the Desktop reader option will not be available 4 Net2 What to...

Page 6: ...1 0 3 7 2 1 1 0 3 4 5 1 1 0 3 4 5 2 2 0 130mA 130mA 130mA 180mA 120mA 120mA Current 12V DC Operating temperature Waterproof HID compatible Handsfree Mounted on metal surface 40 C 66 C 40 F 151 F Specifications http paxton info 1606 5 ...

Page 7: ...port support paxton gmbh de 31 0 76 3333 999 paxton benelux support support paxton benelux com 33 0 157 329356 support paxtonaccess fr paxton support 44 0 1273 811011 paxton support support paxton co uk 27 0 272 14276691 support paxtonaccess co za paxton support 8000 3570 3783 paxton support support paxtonaccess ae 1 864 751 3501 paxton soporte soporte paxton access com 6 ...

Page 8: ...ire is used it must be UL Listed All interconnecting devices must be UL Listed The use of Wiegand readers and the configuration software has not been evaluated by UL For CAN ULC S319 installations terminals leads and wiring methods must comply with CSA C22 1 Canadian electrical code Part 1 safety standards for electrical installations The use of any add on expansion memory or other module manufact...

Page 9: ...être utilisé pour les installations UL294 L utilisation des lecteurs Wiegand et le logiciel de configuration n ont pas été évalués par UL Quand un cable équivalent est utilisé il doit être listé UL Tout appareil d interconnexion doit être listé UL Pour les installation CAN ULC S319 les terminaux câbles et méthodes de câblage doivent être en accord avec CSA C22 1 code électrique canadien Partie 1 s...

Page 10: ...9 ...

Page 11: ...10 ...

Page 12: ... Paxton Ltd 1 0 3 Made in the UK 01 29 2014 ...

Reviews: