Boxed Power Supply assembly 
Instruction set
Figure 8 mains lead

fk1-099

3

Pozi pan self tapping screw - zinc

3

Wall Plugs

1

Cable gland 

1

Cable gland lock nut

IN4001 Diode

10

Cable tie

4

Cable clip

1

Rubber washer

1

M4 Pan head screw

4

PCB pillar

-20 °C

+45 °C

13V DC

13.8V DC

 

2 A
1 A

100V AC

240V AC

+/- 10%

1.2 A 

50 Hz

60 Hz

+/- 3 Hz

232mm

320mm

80mm

236mm

320mm

80mm

150mm

100mm

62mm

Specifications 

Operating temperatures - all items

PSU Electrical 

Output voltage 
Maximum load output current 
Maximum battery charging current
Mains supply voltage  
Mains supply current 
Mains supply frequency 

Environment 

Metal Cabinet 
Plastic Cabinet 
Battery Compartment (Plastic Housing)

Dimensions 

:

The following warnings and instructions MUST be adhered to. Read the instructions before installing and powering the 

equipment. Keep the instructions in a safe place for future reference.

:

RECEIVING INSPECTION-

  Remove any traces of packing material from the unit as such debris may create a fire or shock hazard. 

Unpack the unit with care and inspect for transit damage.  If damage is suspected, the unit must not be used or tested, but should be 

returned to Paxton for investigation and the damage reported to the carrier.

:

INSTALLATION-

  Only qualified and trained personnel, familiar with this type of product and who fully understand these instructions 

should install, connect or test this equipment.  There are no user serviceable parts within the PSU unit.

:

-

 The equipment is intended for indoor use only in dry locations. This is a Class A product. In a domestic environment this product 

may cause radio interference in which case the user may be required to take adequate measures.

:

-

 The installation must meet National Wiring Regulations and IEC60950-1 standards.

:

-

 Disconnect Devices: A readily accessible disconnect device shall be incorporated in the building wiring to include an appropriately 

rated circuit breaker to disconnect both poles with at least a 3.0 mm contact gap. After switch off, all internal capacitors will discharge 

to safe levels within 60 seconds under normal conditions. Under fault conditions, charge may be held for much longer and suitable 

precautions should be taken before handling the unit.

:

-

 Protection device: The fusing characteristics of the protection device to be used are T3.15AH250V

WARNINGS

Min 

Max 

Width 

Height 

Depth 

Waterproof 

No 

Min 

Max 

Features

Battery backup 

Fast/Trickle charge 

Deep discharge protection 
Mains failure alarm (PSU) 
Tamper alarm 

The cabinet can accommodate a 12V / 7Ah battery.
The battery is continuously charged to keep it at maximum capacity. 

If battery voltage falls below 9.5V, it will automatically disconnect - Red LED goes out. 
This pair of voltage free contacts goes open circuit if the mains power fails.

The tamper switch has voltage free contacts that go open circuit if the lid is opened.