The reader port module is designed to convert the 

standard reader ports on Switch2 and Net2 controllers to 

accept one or two RJ45 connections.  Pull off the screw 

terminal block from the reader port and simply replace it 

with this module.

This module can be used to provide a connection 

point for the reader RJ45 plug.  The terminals on 

the module are then wired colour for colour to 

the controller.

Alternatively, the reader can be wired directly 

into the screw terminals of the control unit by 

first cutting off the RJ45 plug and stripping back 

the wires in the cable.

Reader port module  (325-030)

This module may be purchased separately to speed up 

the installation and replacement of readers.

Connection modules 

Further information on how to purchase Installer Tools is available at:  

http://paxton.info/841

Reader junction box  (325-020)

Connection to a control 

unit reader port 

Wiring

Summary of Contents for 390-747

Page 1: ...itting Cable extensions Readers can be extended using Belden CR9540 10 core overall screened cable to a maximum of 100 metres Technical Support Technical help is available Monday Friday from 07 00 19 00 GMT Saturday from 09 00 13 00 GMT 01273 811011 support paxton co uk Documentation on all Paxton products can be found on our website http www paxton co uk ...

Page 2: ... module are then wired colour for colour to the controller Alternatively the reader can be wired directly into the screw terminals of the control unit by first cutting off the RJ45 plug and stripping back the wires in the cable Reader port module 325 030 This module may be purchased separately to speed up the installation and replacement of readers Connection modules Further information on how to ...

Page 3: ...1 LED to check for activity and also the lock wiring Q Red LED is flashing when a card is presented check the validity of the user at the PC Q Check user s access level and ensure they should have access by clicking on Current Validity Q Check the Valid Until date and confirm this has not expired Q Reinstate the ACU from the doors screen Select the ACU s you wish to reinstate and then click OK 4 S...

Page 4: ...ton info 596 Voltage Clock and data bit period Carrier frequency Specifications Operating temperatures all items Electrical Environment Dimensions Min Max Width Height Depth Current Cable length Read Range Token Keyfob Watchprox Waterproof Min Max 5 metres This product is not suitable for retail sale All warranties are invalid if this product is not installed by a competent person ...

Reviews: