1-4 Introduction
Char.
Control
Hex
Dec
Control Action
XON
^Q
0x11
17
Transmitter On
Signals that the device is ready to receive
data (can be sent by the printer or host).
AUXON
^R
0x12
18
Printer on
Signals to the host that the printer is
online. It is sent after initial power up,
clearing a supply jam, or a supply reload.
XOFF
^S
0x13
19
Printer receiver is off
Signals to the host that the print buffer is
full or an error has occurred.
Signals to the printer that the host’s
transmitter is off.
NORM
^T
0x14
20
Switches to 57-column print mode.
AUXOFF ^U
0x15
21
Printer is off
Signals to the host that the printer is out
of supply or has powered down.
CANCEL ^X
0x18
24
Cancel and reset printer
Resets the print buffer places the printer
in initial power-up mode with the default
settings.
ESC
^[
0x1B 27
Escape
Indicates that the following characters are
part of a printer control language
command.
EXTEND ^\
0x1C 28
Extended print
Prints characters double high.
EXTEND
OFF
^]
0x1D 29
Extended print off/Normal print
Prints characters at the normal height.
Summary of Contents for 9430RX