background image

                                                                                                                                                            

EU-DECLARATION OF CONFORMITY

                                                                                                                                                                                       

For the following product:

Pressure transducer DS1/420

is herewith confirmed that this one complies with following EU directives: 

   

 

   EMC directive 2014/30/EU 

   

 

   Ex-protection directive ATEX 2014/34/EU

And developed and examined based on following standards: 

EN 61000-6-3:2011-09   

subject basic standard for emitted interference  – emitted interference  

   

 

    for living quarters, business- and trade as well as small firms  

EN 61000-6-2:2011-06

   subject standard for interference resistance– industrial sector

EN 60079-0:2014-06

      electrical equipment for explosion-hazard areas, 

   

 

 

    section 0: general requirements 

EN 60079-15:2011-02

    electrical equipment for explosion-hazard areas, section 15: construction, 

   

 

    test and marking of electrical equipment of ignition protection type „n“

Marking as category 3 - equipment for use in explosion-hazard areas of the zone 2:

   

 

 

 

 

   II3G  Ex nA IIB T4 X

 

 

     

 

 

 

-20 °C ≤ Ta ≤ +60 °C

Manufacturer:  

                 Paul Wegener GmbH

   

 

 

 

      Marienstraße 24 

   

 

 

 

      D-06493 Ballenstedt

   

 

 

 

      Tel.: +49(0)39483 96 300

   

 

 

 

      Fax.: +49(0)39483 96 400

   

 

 

 

      Internet: www.paul-wegener.de

   

 

 

 

      e-mail:   [email protected]

The safety advice of the product documentation must be followed!

Ballenstedt, 20.04.2016

 

 

        

Wegener

 

 

        Managing 

Director

5

 

 

 

 

 

 

Operating  manual  of  data  acquisition  system  PWBlogg        

Summary of Contents for DS1/420

Page 1: ...Operating manual Data acquisition system PWBlogg Pressure transducer DS1 420 ...

Page 2: ...Paul Wegener GmbH 2 ...

Page 3: ...s are equipped with a pressure equalization element DAE and should preferably be horizontaly positioned This DAE is on the transducer s cover lid as little round label Note that this DAE is not removed or damaged 3 Electrical connection When connecting the transducer eletrically please note that this one won t ever be connected to intrinsically safe circuits Following connecting conditions subject...

Page 4: ... specifications Pressure measuring range Supply 12 30 VDC Output signal 4 20 mA Measurement accuracy 0 2 FS Storage operating temperature 20 C 80 C Compensated temperature range 20 C 80 C Enclosure material Rustproof steel 1 4301 Degree of protection of enclosure IP67 subject to DIN EN 60529 Process port G1 2A Media touching materials Al2O3 viton X5CrNi18 10 X10CRNiS18 9 Explosion protection optio...

Page 5: ...tor EN 60079 0 2014 06 electrical equipment for explosion hazard areas section 0 general requirements EN 60079 15 2011 02 electrical equipment for explosion hazard areas section 15 construction test and marking of electrical equipment of ignition protection type n Marking as category 3 equipment for use in explosion hazard areas of the zone 2 II3G Ex nA IIB T4 X 20 C Ta 60 C Manufacturer Paul Wege...

Page 6: ...Paul Wegener GmbH 6 ...

Page 7: ...7 Operating manual of data acquisition system PWBlogg ...

Page 8: ...ße 24 D 06493 Ballenstedt Tel Fax Internet e mail 49 0 39483 96 300 49 0 39483 96 400 www paul wegener de info paul wegener de Most recent amendment 20 04 2016 Paul Wegener GmbH Paul Wegener GmbH PWB FORM 6033 EN16 ...