background image

SmartNode 5200 Quick Start Guide

3

1.0  Power up the SmartNode

   1.

Connect the SmartNode to a power source using the included power supply and cable. 

   2.

When the 

Power

 LED stops blinking and remains lit, the SmartNode is ready to configure.

2.0  Set your PC to DHCP

This guide will allow you to quickly access the configuration interface of a SmartNode and give an overview of 
the different elements you can or need to configure. For detailed information on all configuration parameters 
refer to the SmartWare software configuration guide.
The SmartNode has a built in DHCP Server which allows an automatic IP connection with a connected PC. To pre-
pare the connection you need to configure the PC to use DHCP. The following paragraphs show how to do this on 
Windows. For other operating systems refer to the operating instructions of the PC.

Electrostatic Discharge (ESD) can damage equipment and impair electrical 
circuitry. It occurs when electronic printed circuit cards are improperly 
handled and can result in complete or intermittent failures. Do the follow-
ing to prevent ESD:
• Always follow ESD prevention procedures when removing and replac-

ing cards.

• Wear an ESD-preventive wrist strap, ensuring that it makes good 

skin contact. Connect the clip to an unpainted surface of the chassis 
frame to safely channel unwanted ESD voltages to ground.

• To properly guard against ESD damage and shocks, the wrist strap 

and cord must operate effectively. If no wrist strap is available, 
ground yourself by touching the metal part of the chassis.

The interconnecting cables shall be acceptable for external use and shall be rated for 
the proper application with respect to voltage, current, anticipated temperature, flam-
mability, and mechanical serviceability.

The interconnecting cables shall be acceptable for external use and shall be rated for 
the proper application with respect to voltage, current, anticipated temperature, flam-
mability, and mechanical serviceability.

CAUTION

CAUTION

CAUTION

VoIPon   www.voipon.co.uk   [email protected]   Tel: +44 (0)1245 808195   Fax: +44 (0)1245 808299 

Summary of Contents for SmartNode 5200

Page 1: ...a light industrial commer cial environment only It is not intended nor approved for use in a heavy industrial or resi dential environment This device is approved for connection to the public ISDN tele...

Page 2: ...earth ground For DC powered devices ensure that the interconnecting cables are rated for proper voltage current anticipated temperature flammabil ity and mechanical serviceability WAN LAN PSTN ports...

Page 3: ...en electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the follow ing to prevent ESD Always follow ESD prevention procedures when removing an...

Page 4: ...Properties TCP IP Properties window 2 Double click on Local Area Connection and click on Properties to open the Internet Protocol TCP IP Properties window see figure 2 3 Select Obtain an IP address au...

Page 5: ...DHCP server to simplify configuration Therefore to automatically config ure the PC for IP connectivity to the SmartNode the laptop PC must be configured for DHCP The SmartNode will provide the PC with...

Page 6: ...assword Enter 192 168 1 1 After you have successfully logged in you are in the operator execution mode indicated by as command line prompt With the commands enable and configure you enter the configur...

Page 7: ...switch connections see figure 4 Figure 4 Connecting the SmartNode to the network You can check the connection with the ping command from the SmartNode to another host on the network 172 16 1 99 if ip...

Page 8: ...Guide for information on configuring the Smart Node device In this example we assume the TFTP server on the host with the IP address 172 16 1 11 and the configuration named SN cfg in the root director...

Page 9: ...ith a VoIP SIP client Online support www patton com E mail support support patton com answered within 1 business day Telephone support Standard 1 301 975 1007 USA Monday Friday 8 00 am to 5 00 pm EST...

Page 10: ...n the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity The safety advice in the documentation ac...

Page 11: ...of their respective owners Warranty Trademark Compliance Information For warranty trademark and compliance information refer to the SmartNode 5200 Getting Started Guide located on the CD ROM shipped w...

Page 12: ..._________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________...

Reviews: