Wiring the Fault Alarm Contact
20
FiberPlex 1008E User Manual
2
• Hardware Description
Figure 13. Power Terminal Block
2.
Tighten the wire-clamp screws to prevent the wires from loosening, as shown in
.
Figure 14. Power Terminal Block
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as shown in
. By inserting the
wires, it will detect the fault status including power failure or port link failure (managed industrial switch only)
and form a normally open circuit. An application example for the fault alarm contact is shown in
Figure 15. Wiring the Fault Alarm Contact
Only use copper conductors,
60/75°C
, tightened to
5 lbs
.
The wire gauge for the terminal block should range between
18~20 AWG
.
IMPORTANT