Connecting the Line Interface
21
CopperLink 1101 Line Power PoE Extender User Manual
2
• Installation
Connecting the RJ-45 Line Interface
Do the following to connect the
Line
interface.
1.
To function properly, the two CL1101s must be connected together using twisted-pair, unconditioned,
dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal
equalization equipment are not acceptable.
2.
The CL1101 is equipped with an RJ-45 interface jack (see
Figure 7. RJ-45 pin-out
3.
The RJ-45 connector on the CL1101’s twisted pair interface is polarity insensitive, and is wired for two,
four, six or eight wires—pin-out to TIA/EIA T568A/B (see
Note
•
2-wire mode
—non-standard pin-out
•
4-wire mode
—802.3i/802.3u wired compatible pin-out
•
8-wire mode
—802.3ab/802.3an wired compatible pin-out
Never connect the Line interface to a PoE port because equip-
ment damage may occur.
Table 1. RJ-45 wire modes
Pair
Pin
Voltage
1+
3
+
1-
6
–
2+
1
+
2-
2
–
3+
4
+
3-
5
–
4+
7
+
4-
8
–