Connecting the CopperLink Line Interfaces
23
CopperLink Model CL1300MDE User Manual
2
• Installation
Figure 7. Installing the device onto the DIN rail
3.
Rotate the device until the lower DIN rail lip snaps into the lower DIN rail clip slot (see callout 2 on
The device has been installed on the DIN rail; proceed to section
“Connecting the CopperLink Line Inter-
Connecting the CopperLink Line Interfaces
To function properly, the CL1300MDE must be connected using a twisted-pair, unconditioned, dry, metal
wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equip-
ment are not acceptable.
The Ethernet Extender is equipped with RJ-45 interface ports
C1
and
C2
on page 24) that con-
form to the T568B standard. As such, any standard Category 5e cable can be used to directly connect two
extenders.
The CL1314MDE has a two-wire interface, and the CL1324MDE has a four-wire interface (see
Note
If you will be installing optional Connect-IT Model 552-E1 surge protectors
to protect the CL1314MDE, refer to
for instruc-
tions.