background image

SmartNode 4654 & 4658  ADSL2+ Quick Start Guide

5

In general, the SmartNode will connect to the network via the 

WAN (DSL) 

port. This enables the SmartNode to 

offer routing services to the PC hosts on 

LAN (ETH 0/))

 port. The SmartNode 4650 ADSL2+ Series provides an 

auto-MDX feature for both Ethernet ports, so you can use a straight-through or cross-over cable to connect to a 
host or a switch (see 

figure 2

). 

Figure 2. 

Connecting the SmartNode to the network

   1.

You can check the connection with the ping command from the SmartNode to another host on the 
local LAN.

 172.16.1.99(if-ip)[eth_dsl]#ping <IP Address of the host>

Note

If the WAN address is 

not

 set to DHCP, to ping a device outside your local LAN you must first configure 

the default gateway. (For information on configuring the default gateway, refer to section “Set IP 
addresses” in Appendix C, “Command Summary” of the 

SmartNode Series SmartWare Software Config-

uration Guide

.)

ACT

LINK

12V

, 1.25A

 

+

Straight-through wired

or crossover cable

LAN (ETH 0/0)

LAN

WAN (DSL)

Network

Summary of Contents for SmartNode 4654 Series

Page 1: ...ecommunication network over BRI S0 ISDN interfaces Zulassung Zugelassen für die Anschaltung an das öffentliche ISDN Telekommunikationnetz an BRI S0 ISDN Schnittstellen Aprobación Este aparato está aprobado para conexión a red publica ISDN sobre interfaz BRI S0 Approbation Cet appareil est approuve pour la connexion au reseau ISDN public avec les interfaces BRI S0 Part Number 07MSN4650A QS Rev C Re...

Page 2: ...ters of the device shall be eas ily accessible and protected by a circuit breaker Ensure that the power cable used meets all applicable standards for the country in which it is to be installed and that it is connected to a wall outlet which has earth ground For units with an external power adapter the adapter shall be a listed Limited Power Source Hazardous network voltages are present in WAN port...

Page 3: ...d IP address 3 1 Factory default IP settings The factory default configuration for the Ethernet interface IP addresses and netmasks are listed in table 1 Both Ethernet interfaces are activated upon power up LAN interface ETH 0 1 LAN provides a default DHCP server The WAN interface uses DHCP client to get the IP address and netmask automatically from the service provider If these addresses match wi...

Page 4: ...ETH 0 0 WAN In this example a network 172 16 1 0 24 is assumed The IP address in example is set to 172 16 1 99 You should set it to the IP address that the network provider has given you Note The examples in this guide use a private IP network with the network address 172 16 1 0 24 192 168 1 1 ctx ip router interface eth_dsl 192 168 1 1 if ip eth_dsl ipaddress 172 16 1 99 255 255 255 0 2002 10 29T...

Page 5: ... Connecting the SmartNode to the network 1 You can check the connection with the ping command from the SmartNode to another host on the local LAN 172 16 1 99 if ip eth_dsl ping IP Address of the host Note If the WAN address is not set to DHCP to ping a device outside your local LAN you must first configure the default gateway For information on configuring the default gateway refer to section Set ...

Page 6: ...with the IP address 172 16 1 11 and the configu ration file named SN cfg resides in the root directory of the TFTP server 172 16 1 99 if ip eth0 copy tftp 172 16 1 11 SN cfg startup config Download 100 172 16 1 99 if ip eth0 After you reboot the SmartNode the new startup configuration will become active 172 16 1 99 if ip eth0 reload Running configuration has been changed Do you want to copy the ru...

Page 7: ...ce FCC Part 15 Class A EN55022 Class A EN55024 Safety Compliance UL60950 1 CSA C22 2 No 60950 1 IEC EN 60950 1 AS NZS 60950 1 PSTN Regulatory Compliance TBR3 AS ACIF S031 AS ACIF S043 ADSL card B 2 Radio and TV interference The SmartNode router generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may caus...

Page 8: ...on of their conformity The signed Declaration of Conformity can be downloaded from www patton com certifications B 5 EG Konformitätserklärung Produktbezeichnung SmartNode 4650 Sendereihe Die bezeichneten Produkte stimmen in der von uns in Verkehr gebrachten Ausführung mit den Vorschriften fol gender Richtlinie überein R TTE 1999 5 EG Richtlinie des europäischen Parlaments und des Rates zur Angleic...

Page 9: ...lassung Zugelassen fur die Anschaltung an das öffentliche ISDN Telekommunikationnetz an BRI S0 ISDN Schnittstellen B 7 Authorized European Representative D R M Green European Compliance Services Limited Avalon House Marcham Road Abingdon Oxon OX14 1UD UK ...

Page 10: ...ented in this docu ment are the property of their respective owners Warranty Trademark Compliance Information For warranty trademark and compliance information refer to the SmartNode 4650 ADSL Series User Manual located online at www patton com manuals ____________________________________________________________________ In accordance with the requirements of council directive 2002 96 EC on Waste o...

Page 11: ...__________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________...

Page 12: ..._______________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ _______________________________...

Reviews: