SW2-4 and SW2-5:  Clock Source

Switches SW2-4 and SW2-5 are set in combination to determine

the synchronous clock source for the Model 1035.

SW2-4

SW2-5

Setting

On

On

Internal transmit clock

Off

On

Receive recover clock

On

Off

External transmit clock

SW2-6:  Carrier Control Method

The setting for switch SW2-6 determines whether the carrier is

“constantly on” or “controlled by RTS”.  This setting allows for operation
in switched carrier, multipoint and/or hardware handshaking
applications.

SW2-6

Setting

Off

Constantly on

On

Controlled by RTS

SW2-7 and SW2-8:  RTS/CTS Delay

The combined settings for switches SW2-7 and SW2-8 determine

the amount of delay between the time the Model 1035 “sees” RTS and
when it sends CTS.

SW2-7

SW2-8

Setting

Off

Off

No delay

On

On

7ms

On

Off

53ms

7

4.0  INSTALLATION

Once the Model 1035 is properly configured, it is ready to connect

to your system.  This section tells you how to properly connect the
Model 1035 to the twisted pair, RS-232 and V.35 interfaces.

4.1  CONNECTION TO THE TWISTED PAIR INTERFACE

The Model 1035 supports communication between two RS-232

devices or two V.35 devices at distances to 6 miles and data rates to 64
Kbps.  There are two essential requirements for installing the Model
1035:

1.

These units work in 

pairs

.  Therefore, you must have one Model

1035 (or a compatible model) at each end of a two twisted pair
interface.

2.

To function properly, the Model 1035 needs two twisted pairs of
metallic wire.  These twisted pairs must be 

unconditioned

, dry,

metallic wire, between 19 and 26 AWG (the higher number gauges
may limit distance somewhat).  Standard dial-up telephone circuits,
or leased circuits that run through signal equalization equipment, or
standard, flat modular telephone type cable, are 

not acceptable

.

For your convenience, the Model 1035 is available with two

different twisted pair interfaces:  RJ-11 jack and  RJ-45 jack.

4.1.1  TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

The RJ-11 and RJ-45 connectors on the Model 1035's twisted pair

interface are pre-wired for a standard TELCO wiring environment (see
Figure 5).  The signal/pin relationships are shown on the table on the
following page:

RJ-11

SIGNAL

RJ-45

SIGNAL

1...................GND

1 .................N/C

2...................RCV

2 .................GND

3...................XMT

3 .................RCV

4...................XMT

4 .................XMT

5...................RCV

5 .................XMT

6...................GND

6 .................RCV
7 .................GND

8 .................N/C

Connection to ground is optional

8

Summary of Contents for RS-232

Page 1: ...ER MANUAL MODEL 1035 Powered High Speed Short Range Modem RS 232 and V 35 versions SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1035 A Doc 054071UA Revised 7 6...

Page 2: ...insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Servi...

Page 3: ...structions on opening the Model 1035 case see Section 3 2 Figure 2 shows the orientation of the switches including the ON OFF positions 3 Figure 2 Close up of configuration switches OFF 1 2 3 4 5 6 7...

Page 4: ...f n a SW1 4 Not Used Off n a SW1 5 Not Used Off n a SW1 6 Not Used Off n a SW1 7 Not Used Off n a SW1 8 V 54 Enable Disable Off Enabled Figure 3 Summary of DIP switch settings for set SW1 SW1 8 V 54 E...

Page 5: ...35 supports communication between two RS 232 devices or two V 35 devices at distances to 6 miles and data rates to 64 Kbps There are two essential requirements for installing the Model 1035 1 These un...

Page 6: ...r host A direct connection to the RS 232 or V 35 DTE port is most desirable If you must use a cable to connect the Model 1035 to the DTE port make sure it is a straight through cable of the shortest p...

Page 7: ...Local Analog Loopback LAL The Local Analog Loopback LAL test checks the operation of the local Model 1035 and is performed separately on each unit Any data sent to the local Model 1035 in this test m...

Page 8: ...problem with the twisted pair line between the modems You should then check the twisted pair line for proper connections and continuity 5 3 3 Using the V 52 BER Test Independently The V 52 BER test c...

Page 9: ...l Loopback 21 From Model 1035 Test Mode 25 1 FG Frame Ground Common 2 Transmit Data A To Model 1035 3 Receive Data A From Model 1035 4 RTS Request to Send To Model 1035 5 CTS Clear to Send From Model...

Reviews: