background image

 

2

 

Model 3088 Quick Start Guide

 

1.0  Select configuration method

 

Before powering up, you must select one of the following methods for configuring your RocketLink-G:

 

 

Plug ‘n’ Play

 

—The RocketLink-G comes factory-configured for Plug ’n’ Play configuration when connected 

to a service-provider network.

 

 

DIP Switch

 

—For deploying the RocketLink-G in back-to-back applications. To use DIP-switch configuration 

you must first set the DIP switches to a position other than all OFF or all ON before powering-up the Rock-
etLink-G. To configure your NTU using the DIP switches, refer to the section entitled “Hardware (DIP-switch) 
configuration” in the 

 

RocketLink-G Model 3088 Series Getting Started Guide.

 

 

Software Configuration

 

—Allows you to modify configurable parameters by connecting a PC to the con-

sole port and issuing software commands. To use software configuration you must set all the DIP switches to 
the ON position before powering-up the RocketLink-G. To configure your NTU via the console port, refer to 
section “Software (CLI) configuration” in the 

 

RocketLink-G Model 3088 Series Getting Started Guide.

 

• This device contains no user serviceable parts. The equipment 

shall be returned to Patton Electronics for repairs, or repaired 
by qualified service personnel.

• AC Powered Units: The external power adaptor shall be a 

listed Limited Power Source. Ensure that the power cable used 
meets all applicable standards for the country in which it is to 
be installed, and that it is connected to a wall outlet which has 
earth ground. The mains outlet that is utilized to power the 
device shall be within 10 feet (3 meters) of the device, shall 
be easily accessible, and protected by a circuit breaker.

• DC Powered Units: The interconnecting cables shall be rated 

for proper voltage, current, anticipated temperature, flamma-
bility, and mechanical serviceability.

• Hazardous network voltages are present in WAN ports, 

regardless of whether power to the unit is ON or OFF. To avoid 
electric shock, use caution when near WAN ports. When 
detaching the cables, detach the end away from the device 
first.

 

 

Do not work on the system or connect or disconnect cables dur-

ing periods of lightning activity.

WARNING

Summary of Contents for RocketLink-G 3088 Series

Page 1: ...and is intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment Document Number 03325U7 001 Rev C Part Number 07M3088 QS R...

Page 2: ...port refer to section Software CLI configuration in the RocketLink G Model 3088 Series Getting Started Guide This device contains no user serviceable parts The equipment shall be returned to Patton El...

Page 3: ...RocketLink G 3 Insert the male plug of the AC power cord into an AC power outlet 100 240 VAC 2 2 Models with external DC power supply The 36 60 VDC DC to DC adapter is supplied with the DC version of...

Page 4: ...d of the cable into the RJ 45 wall socket that provides your G SHDSL service If connecting to another RocketLink G verify the other end of the cable is connected to the DSL port on other RocketLink G...

Page 5: ...on s Model 2 34F25M interface adapter Note The X 21 interface is wired as a DCE If you need to change the orientation ti DTE refer to section Con necting the Model 3088 D X 21 Serial Interface in the...

Page 6: ...sary modifications to maintain uninterrupted service If trouble is experienced with this equipment for repair or warranty information please contact our company If the equipment is causing harm to the...

Page 7: ...epairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for...

Page 8: ...s A 7 Authorized European Representative D R M Green European Compliance Services Limited Oakdene House Oak Road Watchfield Swindon Wilts SN6 8TD UK Die Sicherheitshinweise in der mitgelieferten Produ...

Page 9: ...call sip support patton com Fax 1 253 663 5693 Alternate Patton support for Europe Middle East and Africa EMEA Telephone support Standard telephone support is available five days a week from 8 00 am...

Page 10: ..._________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________...

Page 11: ..._________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________...

Page 12: ..._________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________...

Reviews: