The Model 2720 receiving a RL can be in one of the following states:  

RxPr

The Model 2720 is receiving a preparatory pattern.

Sack

The Model 2720, upon receiving a preparatory pattern,
sends an acknowledgement message.

RL

The Model 2720 is in remote loopback mode.  

RxTr

The Model 2720 is receiving a terminate loopback mes-
sage.  

Wt1s

The Model 2720 is waiting for a sequence of all ones and
will time out if it does not receive it. 

IdleP

The Model 2720 is sending a QRSS, 511 or 2047 pattern.

Off

The Model 2720 is in local loopback.

Test Pattern  Idle 

(default)

Options:  Idle or Sending

To send a pattern, press the ‘c’ key and press <spacebar> to send

the test pattern.  The “OK” message indicates the received test pattern
is error-free.  The “BE” message indicates errors in the received pat-
tern.            

Idle 

Indicates that  Model 2720 is not sending a pattern.

Sending Indicates that 2720 is sending a pattern. 

Error Insertion  Off 

(default)

Options:  On, Off

You may inject intentional errors into the test pattern by turning

Error Insertion ON.  The Error (ERR) LED will blink once per second.

Selected Pattern QRRSS (default)

Options:  QRSS, 511, or  2047

Use this option to select the test pattern used to test the link.

Note: The front panel test pattern switch will initiate the test pattern
selected in this menu (default QRSS).

Network Interface (NI) STATUS

The Network interface (NI) status is shown in

the middle of the Diagnostics/Statistics screen. The brackets are

empty when the link is operating normally. In this example, various two
or three-letter messages are displayed within the brackets, illustrating
what you may see if the Model 2720 is not connected at all or is in a
loss of signal condition. Here are the eight status messages.

Excessive zeros [EXZ], i.e., lack of pulses, detected. This condition
may occur if the unit is not connected to the network, in which case the
EXZ is displayed continuously. If EXZ comes on intermittently, there
may be a frame, line code or data rate mismatch between the near and
far-end units.

Receiver Carrier Loss [RCL]  occurs when 192 consecutive zeros
have been detected at the network interface. RCL clears when a pulse
is detected.

Frame Bit Error [FE]  occurs when there is an error in the framing bit
sequence. This may happen due to a disconnected line, mismatched
framing formats or severe errors in the data stream. This error may
indicate a noisy line or cable condition.  This error may indicate a noisy
line or cable connection if the frames appear to be set correctly. 

Severe Frame Error [SE]  occurs when the framing error exceeds a
certain threshold of errors. This may happen due to a disconnected
line, an extremely noisy connection, or mismatched framing.

Loss of Sync [LOS]  occurs when the T1 framer in the unit cannot
synchronize itself to the received data stream. This may happen due to
a disconnected line.

Out of Frame [OOF] occurs when no valid frame structure can be
found. This may happen due to a disconnected line or mismatched
framing or mismatched framing.

Alarm Indication Signal [AIS]  indicates that the remote unit or the
central office is sending a Blue Alarm, because it is not receiving a sig-
nal; the alarm is an unframed all-ones signal, mainly used to keep the
line alive and to indicate that it is not receiving any signal. This may
indicate that the local unit is receiving a good signal, but that the trans-
mit link may be broken.

c

d

e

Summary of Contents for NetLink 2720/B

Page 1: ...20 B and 2720 C Series NetLink T1 T1 Fractional T1 CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2720 UM Doc 08615U2 001 Rev B Revised 10 26 06 An ISO 90...

Page 2: ...ent as described above Under no con dition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the fol lowing lost profi...

Page 3: ...r and FCC Registration number of the CSU 2 Your telephone company may make changes to its facilities equip ment operations or procedures that could affect the proper functioning of your equipment The...

Page 4: ...or Internal DIP Switches Six Easy to Read LED Indicators Monitor Data Diagnostics Internal External or Network Clocking Also Operates as a High Speed Point to Point Modem Made in USA 2 2 GENERAL PROD...

Page 5: ...rd in which twelve frames make up a superframe All signaling and synchronization are done in band Extended Superframe ESF Extended Superframe as speci fied in AT T TR 54016 consists of twenty four 24...

Page 6: ...S1 2 Tx Clock Select On Transmit data accept with respect to the transmit clock from the 2720 Off Transmit data accept with respect to the external clock from the DTE Switch S2 6 and S2 7 Clock Mode...

Page 7: ...operating parameters Follow the instructions below to configure the Model 2720 using the software selections 1 Plug the 9 pin male end of the cable to your terminal or com puter s DB 9 serial port and...

Page 8: ...the password which can include any character the terminal can generate is 16 characters 6 The Model 2720 will then display the Main Menu screen Patton Electronics Menu Management Enter Password _ 3 2...

Page 9: ...on you can save the changes per manently by executing the Save Changes command This will update the unit s configuration and save all the parameters to permanent memory Logoff For security log off the...

Page 10: ...is a 64 kb s portion of the DS1 frame or super frame to 56 kb s and forcing a pulse in the last data bit to ensure a minimum pulse density in the signal If you must use AMI with a DS0 data rate of 64...

Page 11: ...ANSI developed standard see ANSI T1 403 1995 Network to Customer Installation DS1 Metallic Interface uses the FDL to send and receive one second Performance Report Messages PRMs The messages con tain...

Page 12: ...ions paragraph 3 2 4 on pages 32 and 33 Default Config Source Switch default Option EEPROM Switch The Model 2720 can be initialized via the configuration in the on board permanent memory EEPROM or via...

Page 13: ...e No user controlled loopbacks are active TxPr The Model 2720 is sending the preparatory phase pattern lasting for approximately 2 5 seconds WtAk The Model 2720 is waiting for an acknowledgement from...

Page 14: ...hat you may see if the Model 2720 is not connected at all or is in a loss of signal condition Here are the eight status messages Excessive zeros EXZ i e lack of pulses detected This condition may occu...

Page 15: ...hot of the link performance To clear all counters press the Backspace key If your keyboard does not have this key you can press a two key combi nation to affect the same result Hold down the Ctrl key...

Page 16: ...thout user intervention Note Loop timeout settings are efective only for VT 100 initiated Loops Loops initiated via DTE interface or front panel switch are not affected therefore they must be terminat...

Page 17: ...ies front panel T1 Link Solid green indicates that the end to end TI link is up Signifying that the link is active The TI link LED is off when the link is down TD When the unit sends a one the TD LED...

Page 18: ...unication links These tests can be acti vated via the software control port See Section 3 2 3 System Diagnostics via signals on the serial port interface or the front panel switch 5 2 1 Operating Loca...

Page 19: ...ault and the Local Line Loopback test was successful for both NetLink s you may have a problem with the twisted pair line connection 5 2 3 CSU Loop The NetLink T1 also responds to central office initi...

Page 20: ...witch to either PAT or PAT E Test Pattern with Error Injection c 38 APPENDIX A PATTON NETLINK T1 MODEL 2720 SPECIFICATIONS WAN Speed 1 544 Mbps WAN Connection RJ 48C Nominal Impedance 100 Ohms DTE Int...

Page 21: ...an option Use twisted pair wire with a capacitance of 20pf ft or less Avoid twisted pair wire thinner than 26 AWG i e avoid AWG numbers higher than 26 Use of twisted pair with a resistance greater tha...

Page 22: ...2720 2 Transmit Data To 2720 7 Ground APPENDIX D continued PATTON ELECTRONICS MODEL 2720 INTERFACE PIN ASSIGNMENT M 34 Connector Terminal Interface Pin Signal A GND Earth Ground Shield B SGND Signal...

Page 23: ...Carrier Detect B DCE Source 11 XTC External Transmitter Clock B DTE Source 12 TC Transmitter Clock B DTE Source 13 CTS Clear to Send B DCE Source 14 TD Transmit Data A DTE Source 15 TC Transmitter Cl...

Reviews: