ALM

(Alarm) glows red to indicate that one of
several alarm conditions exist.  These con-
ditions may be local alarms or remote alarm
conditions.  Alarms may occur due to:

• Loss of Synchronization

• Loss of Frame

• AIS (Blue Alarm)

• Yellow Alarm

ERR

(Error) flashes to indicate errors. There are

several flashing patterns to indicate the type

of error. 

Invalid Switch Configuration: It is possible

to request more bandwidth than is possible.

For instance, if you set the starting channel

to 12, and you select a number of timeslots

exceeding 13,  the unit will not be able to

satisfy your request. In that case, the ERR

LED will flash once a second (fi second on,

fi second off). When the unit detects an

invalid setting, it will ignore the setting and

default to a full T1 (bandwidth = 24 chan-

nels, starting channel = 1). This will contin-

ue until you set the switches to a valid set-

ting. The invalid switch configuration condi-

tion overrides other error conditions. Thus, if 

• Errored Second:  In ESF or SF framing, if

the unit detects a frame error, the ERR LED

will flash briefly once a second. 

• Framing Mismatch: the ERR LED flashes

briefly once a second when framing modes

are mismatched.

•  Loss of Signal: When there is no signal

at the network interface, the ERR LED will

flash briefly once a second.

TST

(Test/Loop) glows yellow to indicate that the

unit is in a test mode.  The unit may be in

any one of the following modes:

• D4 Line Loop (CO initiated)
• ESF Line Loop (CO Initiated)

• ESF Payload Loop (CO Initiated)

PWR

(Power) glows green to indicate that the unit

is receiving power.

18

5.2 CENTRAL OFFICE LOOPS

The 2711 also responds to central office initiated loop commands.

When in D4 framing mode, the 2711 will implement the “loop up” com-
mand when it recognizes the pattern “10000” in the data stream for a
minimum of 5 seconds. The “loop down” command is implemented by
the pattern “100” in the data stream for a minimum of 5 seconds.

When operating in ESF framing mode, loopback commands are

issued via the Facility Data Link (FDL).  The line loop message will
cause a loop back before data enters the framer portion of the CSU.
The payload loop message will cause the 2711 to loop data after the
framer portion of the CSU.

The 2711 will respond to Universal Loopback Deactivate to clear

all central office loops.

Summary of Contents for MicroLink-T1 2711 Series

Page 1: ...l T1 CSU DSU SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2711 UM Doc 08606U2 001 Rev D Revised 10 26 06 C E R T I F I E D An ISO 9001 Certified Company Copyrig...

Page 2: ...first date of shipment This warranty is limited to defects in workmanship or materi als and does not cover customer damage abuse or unauthorized modification This product contains no serviceable parts...

Page 3: ...t line power 04DU9 BN 6 0N RJ48C 1 544 Mbps SF and B8ZS without line power 04DU9 DN 6 0N RJ48C 1 544 Mbps ANSI ESF without line power 04DU9 1KN 6 0N RJ48C 1 544 Mbps ANSI ESF and B8ZS w o line power 0...

Page 4: ...to 1 536 Mbps Seven Easy to Read LED Indicators Monitor Data Diagnostics Internal or Receive Loopback Clocking Also Works as a High Speed Point to Point Modem Compact Size Plugs Directly into a Router...

Page 5: ...11 Model 2711s Router Bridge Router Bridge Router 1 544Mbps or nx56 64 1 544MBps or nx56 64 LAN LAN LAN T1 Network 8 3 0 CONFIGURATION Before placing the Model 2711 into service the unit must be con f...

Page 6: ...SW2 2 SW2 1 Clocking Mode Don t Care Off Network Don t Care On Internal Don t Care Off Network Off On Internal On On External CLOCKING MODE Framed Mode ESF D4 Unframed Mode 10 Switches SW1 8 SW1 7 SW1...

Page 7: ...O controls the pulse shape and attenuation of the signal sent to the net work The amount of LBO depends on the distance to the nearest repeater The telephone company providing the T1 service will advi...

Page 8: ...ts of twenty four 24 T1 frames The framing bits are now used for framing CRC and the Facility Data Link FDL The FDL allows maintenance messages and information to be passed between the 2711 and the Ce...

Page 9: ...with 5VDC 300mA to Pin KK See Appendix D for more information DC Power Supply The 36 60 VDC DC to DC adapter is supplied with the DC version of the Model 2711 The black and red leads plug into a DC s...

Page 10: ...ll flash briefly once a second Framing Mismatch the ERR LED flashes briefly once a second when framing modes are mismatched Loss of Signal When there is no signal at the network interface the ERR LED...

Page 11: ...ODEL 2711 SERIES CABLE RECOMMENDATIONS The Patton Model 2711 Series operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted pair cable with the fol...

Page 12: ...120 T1 Nx64 CSU DSU M 34 Male 120VAC 2711 CM UI T1 CSU DSU V 35 M 34 Male UI 07M2711 User Manual 22 APPENDIX D PATTON MODEL 2711 SERIES INTERFACE PIN ASSIGNMENT RJ 48C T1 DS0 Network Interface RJ 48S...

Page 13: ...TD Transmit Data DTE Source R RD Receive Data DCE Source S TD Transmit Data DTE Source T RD Receive Data DCE Source U XTC Transmit Clock DTE Source V RC Receive Clock DCE Sourcce W XTC Transmit Clock...

Reviews: