T1/E1 Diagnostics
139
Model 3086 G.SHDSL Integrated Access Device User Guide
9 • Diagnostics
To set the 3086 T1/E1 port in Network Loopback test, do the following:
1.
Go to the 3086 Main page, select
E1/T1
. Next, click on
Test Modes
, select
network Loop
using the drop
down menu, click on the
Activate Test Mode
button.
2.
Perform a BER (bit error rate) test. Replace the Local T1/E1 equipment (PBX) with a T1/E1 tester, and
initiate a BER test to verify integrity of the cable and operation of the 3086’s T1 interface.
T1/E1 Local Loop
When set to local loop, the 3086/K loops DSL timeslots assigned to carry T1/E1 data to far end 3086 or
3096RC T-DACS.
Figure 15. 3086/K T1/E1 local loop
To set the 3086 in T1/E1 local loop test, follow these steps: