background image

4.3  CONNECTING TO THE DATA PORT

The VDQM universal interface data interface is configured as DCE

(Data Circuit-Terminating Equipment).  It may be configured to
transmit/recieve  V.35, EIA-232 or EIA-422 electrical signals by
appropriately setting switches S1 and S2 (See Section 3.2). 

As a DCE, the High Density 26 pin data port is designed to connect

directly to DTE (Data Termination Equipment), such as a router.   Refer
to the pin assignments in Appendix C to construct a cable to connect
your DTE or DCE equipment.  You may also purchase a connecting
cable directly from cable from Patton Electronics.

4.4  CONNECTING TO AC OR DC POWER 

Instructions for connecting the power supply Universal Interface

AC Power Supply and DC Power Supply option) are contained within
the base unit user manual.  Please refer to the base unit manual for
connection details. 

11

12

5.0  OPERATION

Once the VDQM is installed, it should operate transparently.  This

sections describes FXS and FXO power-up, and general operating
instructions.  

5.1  GENERAL OPERATING INSTRUCTIONS

Both voice ports utilize a Data Access Arrangement (DAA) to

interface with the telephone line.  Both ports also utilize an ADPCM
CODEC to convert the voice to digital information. 

The FXS configuration (Model IM1/JS) has the capability to

generate battery voltage and ring signal.   The battery voltage in the
"On-Hook" condition will be 47 V +/- 10%.  In the "Off-Hook condition
the circuit will supply the required current which meets the country of
installation's V/I curve in accordance with NET- 4.  

The ring signal has the capability to drive a 1 REN load.  This

capability will typically  allow for one phone and an extension to be
connected on a single port or to a single phone with a line length up to
1700 feet since most phones have a REN less than 1.   This will allow
the unit to be placed in a phone closet if desired, as opposed to sitting
on a desk. 

Dialing from an FXS port to an FXO port is accomplished via the

voice channel.  DTMF digits generated by the phone connected to an
FXS port are transmitted to the FXO port.  Dial Pulse dialing is not
permitted. Dialing between two FXS ports is not required.

Summary of Contents for IM 1/J

Page 1: ...MODEL IM 1 J Voice Data Module SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07MIM1J A Doc 090111UA Revised 10 16 98 An ISO 9001 Certified Company USER MANUAL...

Page 2: ...ges include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifica...

Page 3: ...dem products the VDQM combines voice data fax traffic onto a typical 2 wire or 4 wire circuit at speeds up to 768kbps with distances up to 17 4 km The VDQM is the perfect solution for connecting remot...

Page 4: ...irements for a PSTN interface device which is typically defined in NET 4 If a country requirement is not defined in NET 4 it is possible to configure the phone interface to meet those country requirem...

Page 5: ...onnect Module 1 Make sure the power switch on the base unit is off Leave the power cord plugged into a grounded outlet to keep the unit grounded 2 Hold the module with the faceplate toward you and ali...

Page 6: ...ear panel You will see one of the following Model number codes plus a serial number Model IM1 JS FXS Voice Ports Model IM1 JO FXO Voice Ports 9 Figure 4 VDM Rear Panel Voice Port 1 Voice Port 2 4 2 2...

Page 7: ...and general operating instructions 5 1 GENERAL OPERATING INSTRUCTIONS Both voice ports utilize a Data Access Arrangement DAA to interface with the telephone line Both ports also utilize an ADPCM CODE...

Page 8: ...will go off hook passing dial tone and allowing for DTMF dialing A router connected to the Data port of Unit 2 can control the modem connected to the data port of Unit 1 13 1092 e w FXO port 1092 e w...

Page 9: ...Part 68 Surge Protection Voice Ports Tip Ring protected by 320 V sidactor Power Requirements 5V 1 Amp Compliance EN 55022 CE EN 60950 FCC Part15 Class A Control Dipswitch Setup 15 APPENDIX B PATTON E...

Page 10: ...tton Electronics Company All Rights Reserved 13 CTS Clear to Send 12 TC Transmit Clock 11 XTC Network Clock 10 CD Carrier Detect 9 RC Receive Clock 8 CD Carrier Detect 7 SG Signal Ground 6 DSR Data Se...

Reviews: