background image

Model EHA3201

EnviroNET

 

G.SHDSL Router

Quick Start Guide

Important

—This is a Class A device and is intended for use in a light industrial environment. It is not 

intended nor approved for use in an industrial or residential environment.

Part Number: 07MEHA3201-QS, Rev. C
Revised: February 16, 2012

Sales Office: +1 (301) 975-1000

Technical Support: +1 (301) 975-1007

E-mail: [email protected]

WWW: www.patton.com

Summary of Contents for ENVIRONET EHA3201

Page 1: ...intended for use in a light industrial environment It is not intended nor approved for use in an industrial or residential environment Part Number 07MEHA3201 QS Rev C Revised February 16 2012 Sales O...

Page 2: ...evices ensure that the interconnecting cables are rated for proper voltage current anticipated temperature flammabil ity and mechanical serviceability WAN LAN PSTN ports connections may have hazardous...

Page 3: ...static Discharge ESD can damage equipment and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do...

Page 4: ...ed dry metal wire between 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable The G SHDSL Router is equipped with an RJ 45 interface jack Line w...

Page 5: ...G SHDSL Router does not have a power switch so it powers up as soon as it is plugged in There are no user serviceable parts in the EnviroNET G SHDSL Router Fuse replacement should only be performed b...

Page 6: ...C 1 Connect the EHA3201 s Data port to your PC see figure 5 2 The PC used for configuring the EHA3201 should be set for DHCP client 3 Connect the EHA3201 to a power source to turn on the unit 4 The EH...

Page 7: ...Manual For a routed application connecting the CPE to a DSLAM see pages 46 77 in the Model 3201 3241 User Manual 3 0 Additional Information For detailed information about configuring and operating gu...

Page 8: ...AC 110 220VAC 2 25W B 2 Temperature Range 40 185 F 40 85 C B 3 Humidity Up to 90 non condensing B 4 Dimensions 8 H x 9 25 W x 3 25 D B 5 Weight 6 4lb 2 9kg Note For Model 3201 unit specifications refe...

Page 9: ...otify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone com pany will notify the customer as soon as possible Also you will be...

Page 10: ...lity designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect...

Page 11: ...elecommunication Terminal Equip ment and the mutual recognition of their conformity The signed Declaration of Conformity can be downloaded from www patton com certifications C 6 Authorized European Re...

Page 12: ...iability for errors that may appear in this document Trademarks statement The term EnviroNET is a trademark of Patton Electronics Company All other trademarks presented in this docu ment are the prope...

Page 13: ...tart Guide 13 D 0 Buccaneer 400 Series Environmentally Sealed Connectors The following instructions are provided by Bulgin UK for assembling the 400 Series Buccaneer IP68 Sealed Electrical Cable Conne...

Page 14: ...14 EHA3201 Quick Start Guide...

Page 15: ...EHA3201 Quick Start Guide 15...

Page 16: ...16 EHA3201 Quick Start Guide...

Reviews: