6
EnviroNET Quick Start Guide
Switches 2 and 3: Data Rate
Refer to
table 4
for the symmetric line rate settings. (Switch 1 must be in the “
On”
position).
Refer to
table 5
for the asymmetric line rate settings. (Switch 1 must be in the “
Off”
position).
Switches 4, 5 and 6: Ethernet Configuration
Refer to
table 6
to configure Ethernet settings with switches 4, 5, and 6.
Switch 7: Ethernet Shutdown
To enable or disable Ethernet Shutdown, push toggle switch seven (7) up or down.
Refer to
table 7
for settings.
Table 4.
Symmetric CopperLink Line Rates Selection Chart
S2-2
S2-3
Symmetric Line Rate
OFF
ON
50 Mbps
ON OFF
25
Mbps
OFF
OFF
10 Mbps
Table 5.
Asymmetric CopperLink Line Rates Selection Chart
S2-2
S2-3
Asymmetric Line Rates DS/US
ON
ON
50 Mbps/2 Mbps
ON
OFF
16 Mbps/2 Mbps
OFF
OFF
4 Mbps/1 Mbps
Table 6.
Ethernet configurations
S2-4
S2-5
S2-6
Ethernet Configurations
ON
ON
ON
Auto-Negotiate
ON
ON
OFF
100Mb Full Duplex
ON
OFF
ON
100Mb Half Duplex
ON
OFF
OFF
10Mb Full Duplex
OFF
ON
ON
10Mb Half Duplex
Table 7.
Ethernet Shutdown
S2-7
Description
ON
Ethernet Shutdown Enabled
OFF