Figure 2. 

 

Model 2172A standalone rear panel

 

3.1  CONNECTING THE TWISTED-PAIR LINE INTERFACE

 

The Model 2172A supports communication between two peer Ethernet 
LAN sites over a distance of up to 4,250 ft (1.3 km) over 24 AWG 
(0.5 mm) twisted-pair wire.

 

Note

 

Actual distance and link performance may vary depending on 

the environment and type/gauge of wire used.

 

Follow the steps below to connect the Model 2172A CopperLINK Inter-
faces.

 

Note

 

The Model 2172A units work in pairs. One of the units must be 

configured as a (L) Local unit, and the other unit must be config-
ured as a (R) Remote unit. It does not matter which end is the L 
and which is the R. The link is always initiated by the R unit. As 
long as the L unit is powered on, the R unit can establish a link 
by being powered on or by having its power reset.

 

The Interconnecting cables shall be acceptable for 
external use and shall be rated for the proper applica-
tion with respect to voltage, current, anticipated tem-
perature, flammability, and mechanical serviceability.

Lin

e

Po

we

r

M

ad

in 

th

US

A

Et

he

rn

et

Power

jack

Dual 10/100

Ethernet ports

CopperLINK

twisted-pair

RJ-45 interface

   

   

   

   

   

1

CAUTION

Summary of Contents for CopperLINK 2172A

Page 1: ...00 TECHNICAL SUPPORT 301 975 1007 Part 07M2172A UM Rev A Revised 4 8 10 An ISO 9001Certi ed Company This is a Class A device and is intended for use in a light industrial commercial environment only I...

Page 2: ...0Base T Ethernet Interface 11 3 3 Connecting Power 12 4 0 Configuration 12 4 1 Configuring the hardware DIP switches 12 4 2 Configuring DIP Switch S1 14 5 0 Operation 14 5 1 Power Up 14 5 2 Front Pane...

Page 3: ...3 D Distance Chart Based on 24 AWG 0 5 MM 19...

Page 4: ...f or inability to use this product Patton Electronics spe ci cally disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of thes...

Page 5: ...the approximation of the laws of the member states relating to electromagnetic compatibility and Council Directive 2006 95 EC on the approximation of the laws of the member states relat ing to electri...

Page 6: ...le used meets all applicable standards for the country in which it is to be installed For AC powered devices which have 3 conductor power plugs L1 L2 GND or Hot Neutral Safety Protective Ground the wa...

Page 7: ...ent and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the fol lowing to prevent ESD Always f...

Page 8: ...parent operation LED indicators for Power Link Ethernet Link Activity and Remote Local 2 2 DESCRIPTION The Patton Electronics Model 2172A CopperLink modems provide high speed LAN connections between p...

Page 9: ...1 Connecting the Twisted Pair Line Interface on page 10 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100...

Page 10: ...rs One of the units must be con gured as a L Local unit and the other unit must be con g ured as a R Remote unit It does not matter which end is the L and which is the R The link is always initiated b...

Page 11: ...pin relationship is shown in Figure 3 Figure 3 Model 2172A RJ 45 twisted pair line interface 3 2 CONNECTING THE 10 100BASE T ETHERNET INTERFACE The shielded RJ 45 ports labeled Ethernet are the Auto M...

Page 12: ...imum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions 4 0 CONFIGURATION The Model 2172A has four DIP switches S1 for con guring the unit for a wide variety of a...

Page 13: ...4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4...

Page 14: ...atus monitors 5 1 POWER UP Before applying power to the Model 2172A please review section 3 3 Connecting Power on page 12 to verify that the unit is connected to the appropriate power source Table 1 2...

Page 15: ...device is powered off CopperLink Green The port is connected Blinking Green Data transceiving Off No valid link on this port Ethernet Green The port is connected Blinking Green Once the unit connects...

Page 16: ...e 4 250 ft 1 3 km at 1 Mbps upstream 4 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 19 for details A 4 LED STATUS INDICATORS Power Green Coppe...

Page 17: ...Ethernet Extender Kit 2 units preset to local and remote 110 240VAC 07M2172A UM User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal Input Adapter 120 VAC 5V reg DC 1A...

Page 18: ...L 2172A SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6...

Page 19: ...tream US upstream Line Rate Distance in feet km Throughput at Max Distance bits per second 4 1 4250 ft 1 3 km 4 629 408 DS 1 175 328 US 15 2 3500 ft 1 0 km 17 271 744 DS 2 350 656 US 50 2 1250 ft 0 3...

Page 20: ...20 Copyright 2010 Patton Electronics Company All Rights Reserved...

Reviews: