background image

 

4

 

1.0  WARRANTY INFORMATION

 

Patton Electronics

 

 warrants all Model 2168B components to be free 

from defects, and will—at our option—repair or replace the product 
should it fail within one year from the first date of the shipment.

This warranty is limited to defects in workmanship or materials, and does 
not cover customer damage, abuse or unauthorized modification. If this 
product fails or does not performs as warranted, your sole recourse shall 
be repair or replacement as described above. Under no condition shall 

 

Patton Electronics

 

 be liable for any damages incurred by the use of this 

product. These damages include, but are not limited to, the following: lost 
profits, lost savings and incidental or consequential damages arising 
from the use of or inability to use this product. 

 

Patton Electronics

 

 spe-

cifically disclaims all other warranties, expressed or implied, and the 
installation or use of this product shall be deemed an acceptance of 
these terms by the user.

 

Note

 

Conformity documents of all Patton products can be viewed 

online at www.patton.com under the appropriate product page.

 

1.1  REGULATORY INFORMATION

 

EMC Directive:

 

• FCC Part 15, Class A

• EN55022, Class A

• EN55024

 

Low-Voltage Direcive (Safety):

 

• UL60950-1/CSA C22.2 No. 60950-1

• IEC/EN60950-1 2nd Edition

• AS/NZS 60950-1

• A-tick

 

1.2  RADIO AND TV INTERFERENCE (FCC PART 15)

 

This device generates and uses radio frequency energy, and if not 
installed and used properly-that is, in strict accordance with the manufac-
turer's instructions-may cause interference to radio and television recep-
tion. The device has been tested and found to comply with the limits for a 
Class A computing device in accordance with specifications in Subpart B 

Summary of Contents for CopperLINK 2168B

Page 1: ...000 TECHNICAL SUPPORT 301 975 1007 Part 07M2168B UM Rev A Revised 4 8 10 An ISO 9001Certi ed Company This is a Class A device and is intended for use in a light industrial commercial environment only...

Page 2: ...0Base T Ethernet Interface 11 3 3 Connecting Power 12 4 0 Configuration 12 4 1 Configuring the hardware DIP switches 12 4 2 Configuring DIP Switch S1 14 5 0 Operation 14 5 1 Power Up 14 5 2 Front Pane...

Page 3: ...3 D Distance Chart Based on 24 AWG 0 5 MM 19...

Page 4: ...f or inability to use this product Patton Electronics spe ci cally disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of thes...

Page 5: ...the approximation of the laws of the member states relating to electromagnetic compatibility and Council Directive 2006 95 EC on the approximation of the laws of the member states relat ing to electri...

Page 6: ...le used meets all applicable standards for the country in which it is to be installed For AC powered devices which have 3 conductor power plugs L1 L2 GND or Hot Neutral Safety Protective Ground the wa...

Page 7: ...ent and impair electrical circuitry It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures Do the fol lowing to prevent ESD Always f...

Page 8: ...operation LED indicators for Power Link Ethernet Link Activity and Remote Local 2 2 DESCRIPTION The Patton Electronics Model 2168B CopperLink modems provide high speed LAN connections between peered...

Page 9: ...1 Connecting the Twisted Pair Line Interface on page 10 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 2 Connecting the 10 100...

Page 10: ...rs One of the units must be con gured as a L Local unit and the other unit must be con g ured as a R Remote unit It does not matter which end is the L and which is the R The link is always initiated b...

Page 11: ...pin relationship is shown in Figure 3 Figure 3 Model 2168B RJ 45 twisted pair line interface 3 2 CONNECTING THE 10 100BASE T ETHERNET INTERFACE The shielded RJ 45 ports labeled Ethernet are the Auto M...

Page 12: ...imum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions 4 0 CONFIGURATION The Model 2168B has four DIP switches S1 for con guring the unit for a wide variety of a...

Page 13: ...4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4...

Page 14: ...status monitors 5 1 POWER UP Before applying power to the Model 2168B please review section 3 3 Connecting Power on page 12 to verify that the unit is connected to the appropriate power source Table...

Page 15: ...f The device is powered off CopperLink Green The port is connected Blinking Green Data transceiving Off No valid link on this port Ethernet Green The port is connected Blinking Green Once the unit con...

Page 16: ...e 4 250 ft 1 3 km at 1 Mbps upstream 4 Mbps downstream Note Distances depend on selected line rate and line conditions See Appendix D on page 19 for details A 4 LED STATUS INDICATORS Power Green Coppe...

Page 17: ...Ethernet Extender Kit 2 units preset to local and remote 110 240VAC 07M2168B UM User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal Input Adapter 120 VAC 5V reg DC 1A...

Page 18: ...L 2168B SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection C 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6...

Page 19: ...wnstream US upstream Line Rate Distance in feet km Throughput at Max Distance bits per second 4 1 4250 ft 1 3 km 4 629 408 DS 1 175 328 US 9 1 4250 ft 1 3 km 10 364 256 DS 1 176 000 US 16 2 3500 ft 1...

Page 20: ...20 Copyright 2010 Patton Electronics Company All Rights Reserved...

Reviews: