background image

 

USER 

 

MANUAL

 

CopperLink™ Ethernet 
Extenders
Model 2158 & 2168

 

 

Part# 07M2158_2168 Rev. A
Doc# 058091U
Revised 3/24/03

 

An ISO-9001Certified

Company

Summary of Contents for CopperLink 2158

Page 1: ...USER MANUAL CopperLink Ethernet Extenders Model 2158 2168 Part 07M2158_2168 Rev A Doc 058091U Revised 3 24 03 An ISO 9001Certified Company...

Page 2: ...ting Power 12 4 0 Configuration Model 2168 Only 14 4 1 Configuring the hardware DIP switches 14 4 2 Configuring DIP Switch S1 16 Switch S1 1 Ethernet Auto Sense 16 Switches S1 2 and S1 4 Data Rate 16...

Page 3: ...3 D CopperLink Series Interface Pin Assignment 25 D 1 10 100Base T Interface 25 RJ 45 25 D 2 CopperLink Interface 25 RJ 45 25 Terminal Block 25 E Distance Chart Based on 24 AWG 0 5 MM 26...

Page 4: ...xtender generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televisio...

Page 5: ...ics All returns must have a Return Materi als Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Services at Tel 1 301 975 1007...

Page 6: ...settings via DIP switch Model 2168 only Transparent operation LED indicators for Power Ethernet Link Activity CopperLink link Quality of Line QOL Surge suppression up to 20 kA 8 20 s Available in rack...

Page 7: ...at are meant for the remote peered LAN Figure 1 Typical application The CopperLink L modem and CopperLink R modem work together to create a transparent extension between two peered Ethernet LANs Figur...

Page 8: ...ly refer to section 4 0 Configura tion Model 2168 Only on page 14 3 1 STANDALONE UNIT INSTALLATION Do the following 1 Connect the line interface between the units refer to section 3 3 Connecting the T...

Page 9: ...hen that happens gently push the front card forward until it is fully seated in the card edge recepta cle of the rear card it should click into place 4 Secure the front card using the captive fastener...

Page 10: ...ing powered on or by having its power reset 1 To function properly the two CopperLink Ethernet Extenders must be connected together using twisted pair unconditioned dry metal wire between 19 0 9mm and...

Page 11: ...air line interface 3 4 CONNECTING THE 10 100BASE T ETHERNET INTERFACE The shielded RJ 45 port labeled Ethernet is the 10 100Base T interface This port is designed to connect directly to a 10 100Base T...

Page 12: ...nk Ethernet Extender 10 100Base T interface is configured as DTE Data Terminal Equipment If you wish to connect the Copper Link Ethernet Extender to another DTE devices such as 10 100Base T network in...

Page 13: ...l type plug has a 2 5 5 5 10mm I D O D Shaft Length dimensions The CopperLink Ethernet Extender does not have a power switch so it powers up as soon as it is plugged in WARNING There are no user servi...

Page 14: ...switch locations and explains the different configurations 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover located on the underside of the Copp...

Page 15: ...15 Figure 10 Model 2168 standalone modem DIP switch orientation Figure 11 Model 2168 rack card DIP switch orientation...

Page 16: ...Auto sensing capability consists on only auto sensing for 100BaseT half duplex 10BaseT full duplex and 10BaseT half duplex The limited auto negotia tion feature is used when an Ethernet device does no...

Page 17: ...S1 2 S1 3 S1 4 Asymmetric Line Rates DS US OFF OFF ON 4 17 Mbps 1 56 Mbps Mode 0 OFF ON ON 9 38 Mbps 1 56 Mbps OFF ON OFF 16 67 Mbps 2 34 Mbps Table 4 Reserved for future use S1 5 S1 6 S1 7 S1 8 Reser...

Page 18: ...atures nine front panel LEDs five on the rack card that monitor power the Ethernet signals and the Cop perLink connection Figure 12 standalone version and Figure 13 on page 20 rack card version show t...

Page 19: ...ellow However if the LED is solid yellow and the CopperLink Link LED is Off Off when no power is applied to the unit Ethernet Link On green when the 10 100Base T Ethernet link has been established Off...

Page 20: ...o cessor is correcting an error in the data thus prevent ing the transmission of corrupted data to the Ethernet port The more error corrections the more often the LED blinks If the light remains lit c...

Page 21: ...Mbps symmetric upstream downstream A 4 COPPERLINK DISTANCE 6 000 ft 1 83 km at 1 56 Mbps upstream 4 17 Mbps downstream Note Distances depend on selected line rate A 5 COPPERLINK SURGE SUPPRESSOR Gas...

Page 22: ...22 A 8 TEMPERATURE RANGE 32 122 F 0 50 C A 9 HUMIDITY Up to 90 non condensing A 10 DIMENSIONS 1 58H x 4 16W x 3 75D in 10 6H x 4 1W x 8 8D cm...

Page 23: ...Model 2158 no power supply 07M2158_2168 A User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal Input Adapter 120 VAC 5V reg DC 1A Input Adapter 12V PSM 12 VDC Input Ada...

Page 24: ...net Extender Kit includes one local L and one remote R CopperLink Ethernet Extender no power supply 07M2158_2168 A User Manual Power Supplies 08055DCUI 08055 120 5 1 100 240VAC 5V reg DC 2A Universal...

Page 25: ...FACE PIN ASSIGNMENT D 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection D 2 COPPERLINK INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection T...

Page 26: ...s 4 000 ft 1 220 m Symm Line Rate DS US Distance in feet km 6 25 Mbps 4 500 1 37 9 38 Mbps 4 150 1 26 12 5 Mbps 4 000 1 22 16 67 Mbps 3 300 1 00 Asymm Line Rate DS US Distance in feet km 4 17 Mbps 1 5...

Page 27: ..._________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ________...

Page 28: ...____________________________________________ _________________________________________________________ _________________________________________________________ _______________________________________...

Reviews: