Configuring the DAX
61
Access Server Administrators’ Reference Guide
6 • DAX
Main Reference (daxClockMainRef)
The main reference parameter determines which WAN link will supply the clock for the system.
The following settings are available:
•
none(0)—No clock selection. This would be used in conjunction with either a secondary or slave circuit.
•
local-ref-1(1)—Use WAN Port 1 for primary timing. Generally the first WAN connection will be used as
the main reference.
•
local-ref-2(2)—Use WAN Port 2 for primary timing. Generally the second WAN connection will be used as
the fallback reference (see “Fallback Reference (daxClockFallbackRef )”).
•
local-ref-3(3)—Use WAN Port 3 for primary timing.
•
local-ref-4(4)—Use WAN Port 4 for primary timing.
•
local-ref-5(5)—Use WAN Port 5 for primary timing.
•
local-ref-6(6)—Use WAN Port 6 for primary timing.
•
local-ref-7(7)—Use WAN Port 7 for primary timing.
•
local-ref-8(8)—Use WAN Port 8 for primary timing.
•
netref-1(101)—Use to obtain system timing from a slave circuit.
•
netref-2(102)—Use to obtain system timing from a slave circuit.
•
oscillator(200)—Use internal free-run oscillator for the system clock
Fallback Reference (daxClockFallbackRef)
The fallback reference enables the configuration of a back-up clock reference should the main reference fail.
The following settings are available:
•
none(0)—No clock selection. This would be used in conjunction with either a secondary or slave circuit.
•
local-ref-1(1)—Use WAN Port 1 for secondary timing. Generally the first WAN connection will be used as
the main reference.
•
local-ref-2(2)—Use WAN Port 2 for secondary timing. Generally the second WAN connection will be used
as the fallback reference. If there is only one WAN connection, then the fallback reference should be set to
oscillator.
•
local-ref-3(3)—Use WAN Port 3 for secondary timing.
•
local-ref-4(4)—Use WAN Port 4 for secondary timing.
•
local-ref-5(5)—Use WAN Port 5 for secondary timing.
•
local-ref-6(6)—Use WAN Port 6 for secondary timing.
•
local-ref-7(7)—Use WAN Port 7 for secondary timing.
•
local-ref-8(8)—Use WAN Port 8 for secondary timing.
•
netref-1(101)—Use to obtain system timing from a slave circuit.
Summary of Contents for Access Server
Page 24: ...Contents Access Server Administrators Reference Guide 24 ...
Page 28: ...About this guide Model 2960 RAS Getting Started Guide 28 ...
Page 58: ...5 Authentication Access Server Administrators Reference Guide 58 Static User Authentication ...
Page 94: ...7 Dial In Access Server Administrators Reference Guide 94 Dial In User Statistics window ...
Page 110: ...8 Dial Out Access Server Administrators Reference Guide 110 Dial Out User Statistics window ...
Page 134: ...12 Filter IP Access Server Administrators Reference Guide 134 Defining a filter ...
Page 174: ...17 MFR Version 2 Access Server Administrators Reference Guide 174 ...
Page 184: ...17 MFR Version 2 Access Server Administrators Reference Guide 184 MFR Version 2 Modify ...
Page 190: ...18 RIP Version 2 Access Server Administrators Reference Guide 190 RIP Version 2 Statistics ...
Page 196: ...19 SNMP Access Server Administrators Reference Guide 196 Out ...
Page 248: ...23 TCP Access Server Administrators Reference Guide 248 TCP Details ...
Page 252: ...24 UDP Access Server Administrators Reference Guide 252 Introduction ...
Page 258: ...26 License Access Server Administrators Reference Guide 258 End User License Agreement ...