background image

5

6

3.0  CONFIGURATION

The Models 593/25F, 593/45, and 593/TB feature configuration via hard-

ware switches and headers. This section describes all possible hardware config-
urations, including the factory default settings. Table 1 below summarizes config-
uration of switches and headers for the Model l 593/25F, 593/45, and 593/TB.

3.1  DIP SWITCH S2 & S3 

The Models 593/25F, 593/45, and 593/TB feature two eight-position Dip

switches (S2 and S3). These switches are accessed by opening the plastic
case by inserting a small flat blade screwdriver in the slot on either side of the
case and twisting gently. Figure 1A, below shows Models 593/TB & 593/45
bottom view of the printed circuit board and the location of the dip switches.
Figure 1B shows Model 593/45 bottom view of the printed circuit board and the
location of the DIP switches

The Models 593/25F, 593/45, and 593/TB switches (S2-1 thru S2-8 &

S3-1 thru S3-8) can be configured as either “On” or “Off”. Figure 2 shows the
orientation of the DIP switches with respect to ON/OFF positions.

3.1.1  Configuration DIP Switches Sets S2 and S3

The two eight-position Dip switches are used to configure the units for

common asynchronous data rates, full or half duplex over 2-wire/4-wire twisted
pair.  The following sections describe all the possible configurations. 

Figure 2. Close up of DIP switches showing ON/OFF positions.

The switch is shown in the Off  position.

NOTE: 

When selecting any hardware configurations

below, Switch S2 and Switch S3 must be set the same.

S3

ON

OFF

S2

ON

OFF

Figure 1B.  Model 593/25, location of S2 & 

S3 on Printed Circuit Board

S2

ON

OFF

S3

ON

OFF

Figure 1A.  Models 593/TB & 593/45, location 

of S2 & S3 on Printed Circuit Board

Position       Function        ON/OFF     Full Duplex   Half Duplex    Half Duplex

S2-1

TX Mode

HD/FD

OFF

ON

ON

S2-2

Operation

422/485

ON

OFF

OFF

S3-1

TX Mode

HD/FD

OFF

ON

ON

S3-2

Operation

422/485

ON

OFF

OFF

S1-1,2

Interface

2W/4W

OFF

ON

OFF

S1-3

RX IMP.

120    /HI

ON

ON

ON

S1-4

Not Used  (   )

X

X

X

S4-1, 2

Interface

2W/4W

OFF

ON

OFF

S4-3

RX IMP.

120    /HI

ON

ON

ON

S4-4 

Not Used

(   )

X

X

X

Table 1. Configuration summary of swithes and headers  

Switch

Mode

422 4W           485 2W              485 4W

Typical Application Settings

3.1.2 Full/Half Duplex S2-1 and S3-1

Switches S2-1 and S3-1 determine full duplex or half duplex trans-

mission mode.

3.1.3 422/485 Operation S2-2 and S3-2

Switches S2-2 and S3-2 determine RS-422 or RS-485 interface

operation.

Half Duplex

Full Duplex

S2-1 ON

OFF

S3-1

ON

OFF

RS-422

RS-485

S2-2 ON

OFF

S3-2

ON

OFF

Summary of Contents for 593/25, 593/45, 593/TB, RS-422, RS-485

Page 1: ...7 05 00 An ISO 9001 Certified Company 15 APPENDIX B PATTON ELECTRONICS MODEL 593 SERIES EIA 530 PIN CONFIGURATIONS Copyright 1999 Patton Electronics Company All Rights Reserved 7 Signal Ground 3 RD Re...

Page 2: ...st profits lost savings and incidental or consequen tial damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or im...

Page 3: ...nstallation or use of this product please do not hesitate to con tact Patton Electronics Technical Services at 301 975 1007 2 1 FEATURES Asynchronous Operation Half or Full Duplex over 2 or 4 wire lin...

Page 4: ...re the units for common asynchronous data rates full or half duplex over 2 wire 4 wire twisted pair The following sections describe all the possible configurations Figure 2 Close up of DIP switches sh...

Page 5: ...3B Model 593 25 Location of JP7 Pins 1 4 JP8 Pins 1 4 Model 593 Series Data Rate Table Switch Positions Data Rates S2 Position S3 Position 4800 bps 9600 kbps 19 2 kbps S2 3 S3 3 OFF OFF OFF S2 4 S3 4...

Page 6: ...Model 593 TB Terminal blocks with strain relief on both sides 3 Model 593 25F DB 25 female connectors on both sides 4 1 1 4 Wire Connection Using RJ 45 The RJ 45 connectors on the Model 593 45 are pr...

Page 7: ...he cable and feed the cable under the tie wrap which is cur rently installed in the board When you have completed this assembly it should resemble figure figure 5 Connect one pair of wires to XMT and...

Page 8: ...XB 14 4 2 OPERATING THE MODELS 593 SERIES Once the Models 593 25F 593 45 and 593 TB are properly configured and installed it should operate transparently___ as if it were a standard cable con nection...

Reviews: